Table of alarms – Grass Valley 8925EMB-B v.2.1.6 User Manual
Page 52

52
8925EMB-B and -U — Instruction Manual
Service
Table of Alarms
below describes the different type of alarms reported by the module
to the upper level devices, such as the 8900NET module.
Table 4. Summary of Alarms for 8925EMB-U/-B Module
Alarm
Type
Web Page Text Description
FAULT
LED
VID IN
ERR LED
Comments
Status
Reported to
8900Net &
SNMP
Fault
Firmware failure
On
Off
Firmware configuration failure
Yes
Fault
Firmware DCM Not Locked
On
N./A
1
Firmware internal system clock failure
Yes
Fault
Bad firmware image
On
A wrong firmware Image has been down-
loaded
Yes
Fault
Wrong rear module (incompatible with 8925EMB)
On
Yes
Fault
Fiber module failed, replace
On
Yes
Fault
Power supply failure
On
Yes
Warning
Coax video input signal not detected
Flashing
Off
Yes
Warning
Coax video input is invalid or wrong format
Flashing
On
Yes
Warning
Fiber 1 video input signal not detected
Flashing
Off
Yes
Warning
Fiber 1 video input is invalid or wrong format
Flashing
On
Yes
Warning
Fiber 1 video input not supported by hardware
Flashing
Off
The fiber module does not allow Fiber 1
input
No
Warning
Fiber 2 video input signal not detected
Flashing
Off
Video Input Fiber 2 is selected
Yes
Warning
Fiber 2 video input is invalid or wrong format
Flashing
On
Yes
Warning
Fiber 2 video input not supported by hardware
FLASH
Off
Yes
Warning
Hardware configuration does not support selected fiber
video output
Off
Off
Fiber module is a RX/TX and user chooses
to enable fiber TX1 or fiber is dual RX
Yes
Warning
Audio Input 1 signal not detected.
Flashing
N/A
1
Audio Input 1 Monitored but Not Present
Yes
Warning
Audio Input 2 signal not detected.
Flashing
Audio Input 2 Monitored but Not Present
Yes
Warning
Audio Input 3 signal not detected.
Flashing
Audio Input 3 Monitored but Not Present
Yes
Warning
Audio Input 4 signal not detected.
Flashing
Audio Input 4 Monitored but Not Present
Yes
Warning
Audio integrity lost, please delete all HANC inputs
Flashing
User chose to embed a stream without
delete all HANC inputs
Yes
Warning
Coax Video Standard does not match with selection
Flashing
On
Current Coax Video input is not in the
Input Standard Selection table
Yes
Warning
Fiber 1 Video Standard does not match with selection
Flashing
On
Current Fiber 1 Video input is not in the
Input Standard Selection table
Yes
Warning
Fiber 2 Video Standard does not match with selection
Flashing
On
Current Fiber 2 Video input is not in the
Input Standard Selection table
Yes