Functional description – Grass Valley 2000NET v3.1 User Manual
Page 62

62
2000NET Instruction Manual
Functional Description
Functional Description
The 2000NET is designed to allow remote control and monitoring of
modules in a 2000 Series Kameleon frame. It communicates to remote
devices through an Ethernet connection. It communicates with modules in
the frame via the frame bus. It also performs the error monitoring of the
power supplies, modules, temperature and fans. It does error reporting
through on board LEDs, the front panel LEDs, and the frame alarm relay
(via a DB9 connector on the back of the frame).
Refer to the block diagram in
while reading the following func-
tional description.
Figure 41. 2000NET Block Diagram
SDRAM
16 MByte
FLASH
RAM
8 MByte
EEPROM
Flash
Boot
Module
Connector
Diagnostic
Display
Port
Input
Port
CPU
Bus
CPU
Multiplexer
Temperature
Sensors
I2C
SPI
Motherboard Connector
GP I/O
DIP switch
LEDs
Network
Interface
GPI
Optoisolators
A/D
RS232/RS422
Frame Bus
NET COM
Fan
Rotation
Sensor
In
Out
Sel
Out
Sel
Ser. A
Ser. B
Ref.
Power In
+5 V
+3.3 V
DC to DC
Converter
Regulators
PA
PB
PC
PD
8046 -28