Grass Valley 2000NET v3.1 User Manual
Page 46

46
2000NET Instruction Manual
2000NET Module Interface
b.
Select
PROGRAMS
, then
INTERNET TOOLS
, and click on
Xitami Web Server
– 32 bit console
The Xitami Console will open as a DOS window. There will be a log
of events, at least one of which will indicate it is accepting connec-
tions (see
).
Figure 34. Typical FTPD Console Screen
The IP Address line should actually indicate the IP address of the
PC you are using for the FTP server. This is the IP Address that will
be used to initiate the software update.
The line that verifies that the FTPD is running reads:
ready for FTP connections on port 21
7.
With the FTPD running, use the 2000 GUI to initiate software updates.
You will use the web-browser to:
•
Access the appropriate Software Update page for a given module
slot,
•
Enter the required data into the HTML form on that page, and
•
Submit the form.
The 2000 Frame uses the data in the form to contact the FTPD on your
server, download the software update file, and reprogram the targeted
module.
Note
Prior to attempting update of software, refer to the target module’s manual
and confirm that the Remote/Local Only jumper is in the Remote position.
a.
Open a web browser on a PC that is connected over the network to
the 2000 frame.
b.
Enter the URL of the frame where the module to be updated
resides. The frame’s main status page will appear.
Example. Actual
IP Address will be
the one assigned to
your FTP Server PC.
Ready message verifies
the FTPD is running.