Service

2.

If only a specific parameter is read-only, the module may be in a mode
assigning read-only operation to that parameter. Refer to the module’s
instruction manual.

3.

If only the 2000NET module is read-only, the 2000NET module may be
in remote lockout mode.

a.

Check the 2000NET module’s status page to see if the

NET CARD

REMOTE CONTROL

status is disabled.

b.

If so, flip Switch 2 on the S2 DIP switch block (NM CNTRL) to the
enabled setting (see

Table 3 on page 19

)

.

Cannot Connect to the Frame From a VTECS1 VideoFrame Control Panel

1.

Check that the frame is powered and configured with a 2000NET
module on the network.

2.

Check that the control panel has been properly configured with IP
Address, Gateway IP Address, and Subnet Mask. (Refer to the control
panel’s help feature or instruction manual.)

3.

Check that the frame’s correct IP Address has been configured in the
control panel’s frame address.

4.

Check that the control panel is physically connected to the network.

a.

Check that the control panel is connected to a port on an Ethernet
hub.

b.

Check if the L LED (L for link) on the back of the control panel is on.

If the LED indicates no link (off), try a different hub port connec-
tion.

If the LED still indicates no link, change the cable.

If the LED still indicates no link, contact VideoFrame.

5.

Check that the frame is addressable by the control panel.

a.

Check if the T LED (T for transmit) on the back of the control panel
flashes upon the attempt to connect to the frame.

If T does not flash, contact VideoFrame.

b.

Check if the R LED (R for receive) on the back of the control panel
flashes upon the attempt to connect to the frame.

If R does not flash, there may be a problem in the network path
between the frame and the control panel.