beautypg.com

Indicator leds, Table 1 – Grass Valley 2000NET v3.1 User Manual

Page 18

background image

18

2000NET Instruction Manual

Power Up

Indicator LEDs

The frame Status LED, visible on the front cover, reports the conditions
indicated in

Table 1

.

The module LEDs and their possible status and indicated conditions are
shown in

Table 2

.

Table 1. Frame Status LED and Conditions Indicated

LED State

Condition

Green

Frame and all modules functioning properly. Frame locator is inactive.

Red

One or more modules in the frame has detected an internal fault. Frame locator is inactive.

Long Flash Green

Frame locator – flashes when activated by a remote control device. Green indicates frame
and all modules functioning properly.

Long Flash Alternating

Frame locator – flashes when activated by a remote control device. Alternating color indi-
cates one or more modules in the frame has detected an internal fault.

Table 2. Indicator LEDs and Conditions Indicated

LED

LED State

Condition

POWER OK

(green)

Off

Power is off or on-board regulator has failed

On continuously

Module is powered

ETHER(NET)

(green)

Active

Indicates communication taking place on the Ethernet bus

LNK)

(green)

Active

Indicates active link established with another device on the Ethernet bus

PS1

(red)

Off

Power supply 1 is operating normally or is not installed

On continuously

Power supply 1 is present and reporting output not within specified voltage range

PS2

(red)

Off

Power supply 2 is operating normally or is not installed

On continuously

Power supply 2 is present and reporting output not within specified voltage range

PS3

(red)

Off

Power supply 3 is operating normally or is not installed

On continuously

Power supply 3 is present and reporting output not within specified voltage range

PS4

(red)

Off

Power supply 4 is operating normally or is not installed

On continuously

Power supply 4 is present and reporting output not within specified voltage range

TEMP

(red)

Off

2000NET sensors reading temperature within specified parameters

On continuously

Over-temperature condition detected in frame

FP (Front Panel)

(red)

Off

Front Panel is working properly (for use with future front panel)

On

Front Panel has detected an internal fault (for use with future front panel)

REM OVR

(yellow)

Off

Module settings match those set onboard by switches and jumpers

On

One or more settings have been overridden by remote control system (see

Table 3

on page 19

)

COMM

(yellow)

Active

Indicates module is polling the devices on the internal frame communication bus

FAN

(red)

Off

All fans in the frame are working properly

On continuously

At least one fan in the frame is not rotating at its specified rate