Indicator leds, Table 1 – Grass Valley 2000NET v3.1 User Manual
Page 18
18
2000NET Instruction Manual
Power Up
Indicator LEDs
The frame Status LED, visible on the front cover, reports the conditions
indicated in
The module LEDs and their possible status and indicated conditions are
shown in
Table 1. Frame Status LED and Conditions Indicated
LED State
Condition
Green
Frame and all modules functioning properly. Frame locator is inactive.
Red
One or more modules in the frame has detected an internal fault. Frame locator is inactive.
Long Flash Green
Frame locator – flashes when activated by a remote control device. Green indicates frame
and all modules functioning properly.
Long Flash Alternating
Frame locator – flashes when activated by a remote control device. Alternating color indi-
cates one or more modules in the frame has detected an internal fault.
Table 2. Indicator LEDs and Conditions Indicated
LED
LED State
Condition
POWER OK
(green)
Off
Power is off or on-board regulator has failed
On continuously
Module is powered
ETHER(NET)
(green)
Active
Indicates communication taking place on the Ethernet bus
LNK)
(green)
Active
Indicates active link established with another device on the Ethernet bus
PS1
(red)
Off
Power supply 1 is operating normally or is not installed
On continuously
Power supply 1 is present and reporting output not within specified voltage range
PS2
(red)
Off
Power supply 2 is operating normally or is not installed
On continuously
Power supply 2 is present and reporting output not within specified voltage range
PS3
(red)
Off
Power supply 3 is operating normally or is not installed
On continuously
Power supply 3 is present and reporting output not within specified voltage range
PS4
(red)
Off
Power supply 4 is operating normally or is not installed
On continuously
Power supply 4 is present and reporting output not within specified voltage range
TEMP
(red)
Off
2000NET sensors reading temperature within specified parameters
On continuously
Over-temperature condition detected in frame
FP (Front Panel)
(red)
Off
Front Panel is working properly (for use with future front panel)
On
Front Panel has detected an internal fault (for use with future front panel)
REM OVR
(yellow)
Off
Module settings match those set onboard by switches and jumpers
On
One or more settings have been overridden by remote control system (see
COMM
(yellow)
Active
Indicates module is polling the devices on the internal frame communication bus
FAN
(red)
Off
All fans in the frame are working properly
On continuously
At least one fan in the frame is not rotating at its specified rate