Power up, Rebooting the module – Grass Valley 2000NET v3.1 User Manual

Page 17

background image

2000NET Instruction Manual

17

Power Up

Power Up

The various front LED indicators and configuration switches are illustrated
in

Figure 12

. Upon power-up, all LEDs should light for the duration of the

initialization process. If all LEDs remain on, the module may not be fully
seated in its slot. After initialization the Power OK LED (PWR) will be on
and the red Network Module LED (NM) should go off. All other LEDs
report detected conditions within the frame and the installed modules. If
the NM LED does not go off, the board needs servicing.

Figure 12. LEDs and Configuration Switches

The Frame Status LED is visible through the frame front cover.

Table 1

and

Table 2 on page 18

describe the module LEDs and the conditions they indi-

cate.

Rebooting the Module

If you need to reboot the 2000NET module, either remove and replace the
module in the slot or use the GUI to access the Configuration or Network
pages. Both pages have a

Reboot

button (see

2000NET Module Interface

on

page 29

).

8046-02

Power OK (PWR) green

Remote Override (REM OVR) yellow

Power Supply 1 (PS1) red

Front Panel (FP) red

Power Supply 3 (PS3) red

Fan Health (FAN) red

Module Health (MOD) red

Frame Bus (FB) red

Ethernet (ETHER) green

Ethernet Link (LNK) green

Power Suppy 2 (PS2) red

Power Suppy 4 (PS4) red

Temperature (TEMP) red

Bi-color
Frame Status LED
(STATUS) red/green

Communication (COMM) yellow

Network Module (NM) red