beautypg.com

Connecting irf physical interfaces – H3C Technologies H3C SecPath F5020 User Manual

Page 45

background image

36

Step Command

Remarks

3.

Bind a physical

interface to the IRF
port.

port group interface
interface-type
interface-number
[ mode

{ enhanced | normal } ]

By default, no physical interfaces are bound to
any IRF port.
Repeat this step to assign multiple physical
interfaces to the IRF port.
Each IRF port can have a maximum of eight
physical interfaces.
When you bind physical interfaces to an IRF

port, set all the physical interfaces to the same
mode: enhanced or normal.
If you do not specify a mode, the enhanced
mode applies.

Saving configuration to the next-startup

configuration file

Save the running configuration before converting to the IRF mode. The mode change requires a reboot,

which causes all unsaved settings to be lost.
Perform the following task in any view:

Task Command

Save the running configuration to
the next-startup configuration file. save [ safely ] [ backup | main ] [ force ]

Connecting IRF physical interfaces

Connect the devices into a daisy chain.
When you connect two neighboring IRF members, connect the physical interfaces of IRF-port 1 on one

member to the physical interfaces of IRF-port 2 on the other (see

Figure 15

).

IMPORTANT:

Do not connect physical interfaces of both IRF ports on one member device to the physical interfaces of
both IRF ports on the other.

No intermediate devices are allowed between neighboring members.

Figure 15 Connecting IRF physical interfaces