Recommended AC power connector

A three-terminal, single-phase power connector with a grounding contact is recommended. Normally,

the grounding contact of the power supply system in a building was buried during construction and
cabling. Before connecting the AC power cord, you must make sure that the power supply of the building

has been well grounded.

Connecting the AC power cord

Step1

Make sure that the PGND is securely connected to the ground.

Step2

Move the power switch of the router to the OFF position, and connect one end of the power cord shipped

with the router to the power socket on the rear panel, and the other end to an AC power source.

Step3

Move the power switch to the ON position.

Step4

Check whether the power LED on the front panel of the router is ON. If the power LED is ON, the power

cord is properly connected.

Installing Antennas

Fasten the attached antennas onto the router. Avoid over-tightening. Once the network is up and running,

you may need to adjust the antennas to achieve better coverage. Usually, the antennas should be vertical

to the ground or ceiling to achieve the optimal coverage, as shown in the following figure.

Figure 18 Installation of router antenna

CAUTION:

Do not touch the antenna top, especially after the antenna is connected with the grounding contact.
Otherwise electrostatic discharge (ESD) may damage the router.

Connecting the Console Terminal

Console interface

MSR 20-1X routers each provide an RS232 asynchronous serial console (CON) interface for router

configuration.