Recommended AC power connector
A three-terminal, single-phase power connector with a grounding contact is recommended. Normally,
the grounding contact of the power supply system in a building was buried during construction and
cabling. Before connecting the AC power cord, you must make sure that the power supply of the building
has been well grounded.
Connecting the AC power cord
Step1
Make sure that the PGND is securely connected to the ground.
Step2
Move the power switch of the router to the OFF position, and connect one end of the power cord shipped
with the router to the power socket on the rear panel, and the other end to an AC power source.
Step3
Move the power switch to the ON position.
Step4
Check whether the power LED on the front panel of the router is ON. If the power LED is ON, the power
cord is properly connected.
Installing Antennas
Fasten the attached antennas onto the router. Avoid over-tightening. Once the network is up and running,
you may need to adjust the antennas to achieve better coverage. Usually, the antennas should be vertical
to the ground or ceiling to achieve the optimal coverage, as shown in the following figure.
Figure 18 Installation of router antenna
CAUTION:
Do not touch the antenna top, especially after the antenna is connected with the grounding contact.
Otherwise electrostatic discharge (ESD) may damage the router.
Connecting the Console Terminal
Console interface
MSR 20-1X routers each provide an RS232 asynchronous serial console (CON) interface for router
configuration.
describes the attributes of the console interface.
Table 16 Attributes of the console interface
Item Description
Connector type
RJ45
Interface standard
RS232