Grounding the router

WARNING!

Correctly connecting the router grounding cable is crucial to lightning protection and EMI protection.

IMPORTANT:

The resistance reading should be less than 5 ohms between the chassis and the ground.

The MSR 26-00-10 router, MSR 26-00-17 router, and MSR 26-30 router each comes with a grounding
cable. The MSR 26-00-5 router comes with a ring terminal but no grounding cable. You need to

purchase a grounding cable for the MSR 26-00-5 router.

Attaching the ring terminal

1.

Use the wire-stripping pliers to strip 5 mm (0.20 in) of insulation sheath off one end of the

grounding cable.

240m

m 9

.45in