Jpeg2000 stand alone dvr user guide – ARM Electronics JHD User Manual
Page 30
JPEG2000 Stand alone DVR User Guide
- 30 -
[MOTION MASK SETUP]
Users can set up which area to detect motion and which not to detect. The area
that is marked not to detect motion is Grey.
Press the number button to select the channel.
Set motion detection area. Use the Direction buttons to move the cursor and
press [ENTER] to mark the area.
Press [Mode] to change the editing mode. The editing modes are as below:
1.Cell: Move to the desired location and press [ENTER] to activiate or
deactiviate the motion detection in the marked area cell by cell.
2.ALL ON: Change the mode to ALL ON and press ENTER to activate the motion detection in the whole window.
3. ALL OFF: Change the mode to ALL OFF and press ENTER to deactivate the motion detection in the whole
window.
4.BLOCK ON: Block an area to activate the motion detection in the desired area. Move the cursor to a corner cell of
the desired area and press ENTER to mark the starting cell of the block. Then, move the cursor to the cell at the
diagonal end of the desired area and press ENTER to finish marking the block. When the window is at the ALL OFF
mode, you can activate the motion detection in the block.
5.BLOCK OFF: Block an area to deactivate the motion detection in the desired area. The setup steps are the same
as BLOCK ON. If the window is at the ALL ON mode, you can deactivate the motion detection in the block you
make.
CELL [1]
Channel
Edit
mode
4-3-4 Interval setup
1.[SWITCH INTERVAL]
FULL-
Full Screen Sequence Interval setup. (Range: 1~99 SEC)
PIP-
Picture in Picture, the sub-picture’s sequence interval setup. (Range:
1~99 SEC)
2.[EVENT RECORD]
Event Update Time is to avoid the DVR from recording the event logs from the
same event. The event types include alarm, motion and video loss. When an
event is triggered, it is possible that the same event keeps on being triggered
for a period of time. With the help of Event Update Time, whenever there is an
event, the DVR records the starting time and information of the event in the
Event Log, and ignores the following events within the duration set in the Event
update time. The setting range of the Event Update time is from 10 seconds to
990 seconds.
Note:Please go to [RECORD SETUP] > [SCHEDULE RECORD] and change
the record mode to MOTION to activiate the MOTION settings.