AML M2500 Decoder User Manual
Page 52

48
4) LASER / CCD CONTINUOUS RUN
ON
The LASER or CCD runs continuously as long as the
trigger is pulled. The scanner will not be affected by
the LASER/CCD TIMEOUT and will not shut off after
a "good read".
OFF *
The LASER or CCD runs only when the trigger is
pulled. (The LASER/CCD TIMEOUT option remains
in effect.)
5) CONTINUOUS RUN READ DELAY (0.0 - 9.9 SEC)
(Valid only if option (4) above is ON.) This option sets the
DELAY period between successive reads of the same bar
code. This allows the removal of the bar code from the
scan field without multiple reads. The default setting is 1.0
second. (To select a value, for example, 2.0, scan the "2"
label, then the "0" label.)
6) BAR CODE FUNCTION KEYS
ON
Applies to BAR CODE data, preambles,
postambles, and user defined termination
characters. FUNCTION KEYS F1 through F10 will
be transmitted in place of the ASCII characters
"DC1" (11H) through "SUB" (1AH). The
FUNCTION KEY values are listed in the Full ASCII
Chart on back of the MENU, and in Appendix A.
OFF *
Disable FUNCTION KEYS.
(Standard ASCII characters are transmitted.)
NOTE: This option is applicable only if the "TRANSMIT
DATATYPE = PC SCAN CODES" or if you are
using SOFTCOM keyboard emulation software.
7) KEYBOARD CAPS LOCK STATUS
ON *
Scan ON to indicate that the keyboard's CAPS
LOCK is turned ON. The result is lower case
Alpha characters being output as Shifted
characters.
OFF
Scan OFF to indicate that the keyboard's CAPS
LOCK is turned OFF. The result is upper case
Alpha characters being output as Shifted
characters.
NOTE: This option is applicable only if the "TRANSMIT
DATATYPE = PC SCAN CODES" or if you are
using SOFTCOM keyboard emulation software.