Welltech WG5290 User Manual
Page 65

Welltech Computer Co., Ltd.
WellGate 5290 User Guide – V6.1
- 65 -
• Src Num Type: ISDN source number type
• Dest Num Type: ISDN destination number type
• Src Num Presen: ISDN source number presentation
• Src Num Screen: ISDN source number display
• Input Gain: Voice Gain from PSTN to IP side (default: 0 db)
• Output Gain: Voice Gain from IP to PSTN side (default: 0 db)
• Q.931 General Opt.: used for Q.931 general behavior.
o
0x00000001: No sending of STATUS message on receipt of an
unknown IE. If this bit is set, then ISDN Stack does not generate a
STATUS message after having received a message containing 1 or
more unknown/unrecognized IE(s). This bit applies only for network
variants for which the sending of STATUS in this case is optional
(where recommendation says “ a SATUS MAY be returned”)
o
0x00000002: No sending of STATUS message on receipt of an
optional IE with invalid content. If this bit is set, then ISDN Stack
does not generate a STATUS message after having received a
message containing 1 or more optional IE(s) with invalid content.
This bit applies only for network variants for which the sending of
STATUS in this case is optional (where recommendation says “a
STATUS MAY be returned”).
o
0x00000004: Unknown/unrecognized Facility IE accepted. If this bit
is set, then NS does not reject a received message containing a
Facility IE that it does not recognize and acts as if the IE was
correct. It applies in network variants where a complete ASN1
decoding is made on Facility IE
o
0x00000080: Only applicable when configuration is Euro ISDN,
User-side, outgoing call . If this bit is set, then the board sends a
CONNECT_ACK message when receives a CONNECT.
o
0x00000100: Only applicable when configuration is ETSI. If this bit
is set, BC and HLC IE’s in Alert, CALL_PROC, CONNECT and
PROGRESS message are rejected.
o
0x00000200: Only applicable when configuration is 4ESS, DMS,
5ESS, N12 or HKT, NFAS-both incoming and outgoing calls. If this
bit is set, then ISDN calls on NFAS have an interface ID different to
the default one (refer to NFAS Appendix). The interface ID value is
taken from the Board param of the NFAS Member Trunk config.
(i.e.,board_params. Trunk Config[i]. Protocol Specific. ISDN Trunk.
ISDN_NFAS_Interface ID).
o
0x00000800: Only applicable when configuration is 4ESS, DMS,
5ESS or N12. If this bit is set, the channel ID is always set to
EXPLICIT interface ID, even if the B-channel is on the link bearing
the D-channel.
o
0x00008000: Only applicable when configuration is ETSI. If this bit
is set, Mu-law (μ-Law) is also accepted. Otherwise, only A-law is
accepted.
o
0x00010000: Only applicable when configuration is ETSI. If this bit
is set, calling party number octet 3a is always present, even if
presentation and screening have default values. Otherwise, usual
rule is used.