• Outbound DM Group: Digit Manipulation group used for outgoing calls

• Local Ring Back: Provide ring back tone for PSTN or not. It only works

when VoIP outgoing Fast Start is disabled.

• Channel Mask: Channel mask for incoming or outgoing calls (default:

0xffffffff)
Start from MSB each bit, indicate a time, slot a trunk (e.g. 0x0000ffff:
0~15 B channel mask, 17~31 B channel free)

• Clock Master: PSTN trunk clock source

• Framing Method: Automatic framing

• SS7 Circuit Group Mode: Enable the this SS7 Circuit group (IN Service)

or not (Out Service)

• SS7 Group ID: Circuit Group ID in SS7 config.txt (refer to

ISUP_CFG_CCTGRP gid)

• SS7 Circuit Identifier 1: First CID in SS7 config.txt (refer to

ISUP_CFG_CCTGRP base_cid)

• SS7 Circuit Identifier Count 1: set to 15 (internal user only)

• SS7 Circuit Identifier 2: Start CID for time slot 17 (refer to

ISUP_CFG_CCTGRP based_cid + offset)

• SS7 Circuit Identifier Count 2: set to 15 (internal use only)


Advance Trunk Configuration:
Start Path: Configuration>Interface>Trunk>Advance

Figure 7.5-2


Advance Parameter Description:

• Interface ID: System parameter

• Trunk ID: System parameter

• Src Num Plan: ISDN source number plan