Welltech WG5290 User Manual
Page 64

Welltech Computer Co., Ltd.
WellGate 5290 User Guide – V6.1
- 64 -
• Outbound DM Group: Digit Manipulation group used for outgoing calls
• Local Ring Back: Provide ring back tone for PSTN or not. It only works
when VoIP outgoing Fast Start is disabled.
• Channel Mask: Channel mask for incoming or outgoing calls (default:
0xffffffff)
Start from MSB each bit, indicate a time, slot a trunk (e.g. 0x0000ffff:
0~15 B channel mask, 17~31 B channel free)
• Clock Master: PSTN trunk clock source
• Framing Method: Automatic framing
• SS7 Circuit Group Mode: Enable the this SS7 Circuit group (IN Service)
or not (Out Service)
• SS7 Group ID: Circuit Group ID in SS7 config.txt (refer to
ISUP_CFG_CCTGRP gid)
• SS7 Circuit Identifier 1: First CID in SS7 config.txt (refer to
ISUP_CFG_CCTGRP base_cid)
• SS7 Circuit Identifier Count 1: set to 15 (internal user only)
• SS7 Circuit Identifier 2: Start CID for time slot 17 (refer to
ISUP_CFG_CCTGRP based_cid + offset)
• SS7 Circuit Identifier Count 2: set to 15 (internal use only)
Advance Trunk Configuration:
Start Path: Configuration>Interface>Trunk>Advance
Figure 7.5-2
Advance Parameter Description:
• Interface ID: System parameter
• Trunk ID: System parameter
• Src Num Plan: ISDN source number plan
• Dest Num Plan: ISDN destination number plan