beautypg.com

Welltech WG5290 User Manual

Page 62

background image

Welltech Computer Co., Ltd.

WellGate 5290 User Guide – V6.1

- 62 -

Figure 7.5-1


Basic Parameter Description:

• Interface ID: System parameter

• Trunk ID: System parameter

• Trunk Type: T1or E1 selection (SS7 support E1 only)

• Description: Description for this trunk ID

• Termin Side: Network site or User Site (normally, you set to “user side

when connect to switch)
o

User

Side

o

Network

Side

• Trunk Mode: Trunk operation mode

o

Disable: Disable the trunk

o

Normal: Accept PSTN and VoIP calls

o

PSTN incoming only: Allow the PSTN incoming calls only

o

VOIP incoming only: Allow the VOIP incoming calls only

• Hunting Method: PSTN trunk hunting method for available channel

o

Random: Hunt randomly

o

Cyclic: Initial hunt (after power-up/reboot) begins with B channel 1;

subsequent hunts begin with position following last successfully
allocated resource

o

Rotary: Hunt always begins with B channel 1

o

Reverser Rotary: Hunt always begins with B channel 31