Output settings – Wavetronix SmartSensor Matrix (SS-225) - User Guide User Manual
Page 87
86
CHAPTER 8 • ZONES & CHANNELS
Figure 8.12 – Output Settings (Normal, Counting, Pulse)
˽
Detector Input – The Detector Input number provides a way for you to map inputs to
the intersection phase in the controller. By default, the Detector Input will be set to
“00;” if the input is left at “00,” then it is unassigned. This setting is for reference pur-
poses only and does not actually change the sensor.
˽
Phase – Since the SmartSensor Matrix is capable of monitoring more than one phase,
this setting allows you to enter the phase number that most closely represents the phase
the sensor is monitoring. By default, the Phase will be set to “00;” if the phase is left
at “00,” then it is unassigned. This setting is for reference purposes only and does not
actually change sensor operation.
˽
Channel Type – This drop-down list allows you to select the type of channel (Normal,
Counting or Pulse). A normal channel is presence detection; a counting channel is
a special pulse based on counting algorithms; and a pulse channel is a generic pulse
based on zone presence.
˽
Invert – This option allows the channel output to be inverted (i.e. channel output de-
faults to on, then switches off when a vehicle is detected).
˽
Min/Max Speed – Use this option to select minnimum and maximum speeds for the
channel.
Output Settings
The extend and delay settings can also be specified using the Output Settings button. This
button will open a window that will allow you to select individual channels to edit and also
to specify the minimum pulse width and pulsed channel width (Figure 8.13). The minimum
pulse width is the minimum duration a presence detection will be signaled via the contact
closure rack cards. The pulsed channel width is the duration the contact closure message
lasts for a pulse or counting channel. All output settings are specified in seconds.