Wavetronix SmartSensor Matrix (SS-225) - User Guide User Manual
Page 28
CHAPTER 2 • CABINET SOLUTIONS
27
Note
If you’re using a preassembled backplate, the plug features two measures to ensure
that it’s always returned to their correct terminal block sections.
First, for visual confirmation, one part of the plug is blue (see Figure 2.7) and must be
visually matched up to a blue terminal block. The location of the blue piece rotates in
the different plugs and terminal block sections: in the first, the first block is blue, in
the second, the second is blue, etc.
Second, the plugs are keyed, as shown in the blue piece in Figure 2.7, so they will only
fit into their correct terminal block sections.
Wire Color
Signal
Red (PWR)
DC+
Black (GND)
DC-
White with Blue stripe (485+)
Control bridge 485+ (port1)
Blue (485-)
Control bridge 485 - (port 1)
White with Orange stripe (485+)
Data bus 485+ (port 2)
Orange (485-)
Data bus 485- (port 2)
Bare metal (DRN)
Drain
Table 2.1 – Cable Wiring Color Code