Applying Silicon Dielectric Compound
Use the following steps to correctly apply the silicon dielectric compound:
1 Tear the tab off the tube of silicon dielectric compound.
2 Squeeze about 25% of the silicon into the connector at the base of the SmartSensor as
shown in Figure 1.5. Be sure to wipe off any excess compound.
Figure 1.5 – Applying Silicon Dielectric Compound
Connecting the SmartSensor Cable
1 Attach the cable connector to the 25-pin connector at the base of the SmartSensor as
shown in Figure 1.6. The SmartSensor connector is keyed to ensure proper connection;
simply twist the connector clockwise until you hear it click into place.
2 Strap the cable to the pole or run it through a conduit to avoid undue movement from
wind and reduce cable strain.
Figure 1.6 – Attached Cable