Test details screen, Test details screen -41 – Verilink WANsuite 5330 (34-00302.F) Product Manual User Manual
Page 69
![background image](https://www.manualsdir.com/files/808571/content/doc069.png)
W e b S e r v e r I n t e r f a c e
3-41
Figure 3.30
Diagnostics Screen
Description
Describes the type of interface selected for testing.
Loop Type
Describes the type of loop test (if any) performed on the selected interface.
Setting
Displays the bandwidth on which you wish to perform the BERT.
Pattern
Specifies the pattern to be transmitted during a BERT for the selected port.
Length
Displays the length of time for which the BERT should run for the selected
interface.
State
Displays the current BERT state for the selected interface.
Elapsed Time
Displays the time elapsed since a BERT began or, if completed, the total test
time.
BE
Displays the total number of bit errors detected since the BERT began or
since error statistics were last cleared.
ES (Errored Seconds)
Displays the number of asynchronous errored seconds that have been detected
since the BERT began or since error statistics were last cleared. This
parameter includes bit error seconds and sync loss seconds.
% EFS
Displays what percent of the total BERT time ran error free. This ratio is
derived from the number of error-free seconds divided by the number of
seconds accumulated in Elapsed Time.
Test Details Screen
The Test Details screen (Figure 3.31) lets you set some test parameters and
view other read-only parameters. This screen is also used to initiate a BERT
or Loop Test. The Network Interface Test Details screen, shown in Figure
3.31, and the Serial Interface Test Details screen contain the same BERT
Table parameters, which are described below. However, their Loop Tables at
the bottom of the screen contain different options, which are also described
below.