Verilink WANsuite 5330 (34-00302.F) Product Manual User Manual
Page 32
![background image](https://www.manualsdir.com/files/808571/content/doc032.png)
3-4
W A N s u i t e 5 3 3 0
The Unit screen provides the following user-activated buttons:
Maintenance Reset
Use this button to access a screen where you can perform a Maintenance
Reset (Figure 3.2). When you click on the arrow in the pull-down menu box
on the screen, you will have the option to perform a TDM, Packet, or Packet
4 reset. When you select one of these options, all previous configurations will
be lost and the unit will be set back to the specified factory default.
Figure 3.2
Maintenance Reset Screen
NOTICE:
Performing a “Maintenance Reset” or a “Save and Restart” will
terminate communications with the unit. A “Refresh” should be
performed after approximately 10 seconds to restore communications.
Save and Restart
Use this button to save the current configuration settings and then restart the
unit. Clicking the “Save and Restart” button on the Unit screen will display a
confirmation screen as shown in Figure 3.3 below. Click the “Save and
Restart” button on the confirmation screen to confirm the action.
Button
Function
Submit
Sets any values that have been changed. The top “Submit”
button sets any unit parameters changed in the upper section of
the screen, and the lower “Submit” button sets the real-time
clock.
Maintenance Reset
Resets unit to its default TDM or Packet configuration.
Save and Restart
Saves the current configuration and restarts the unit.
Refresh
Refreshes data on the current page.