W e b S e r v e r I n t e r f a c e

3-7

Reset Timer

The status table also provides a means for establishing the Reset Timer
threshold. This read/write field is used to establish the contiguous number of
seconds that an alarm parameter must be clear before the alarm is reset.
Applicable values range from 000 through 900. A value of “000” means the
alarm will never be reset. The default value is 30.

The Network screen provides the following user-activated buttons:

Serial Screen

The Serial screen (Figure 3.5) lets you view and make configuration changes
to the unit’s Serial interface as described below. To make changes to any
Serial port parameter, simply set the parameter to the desired selection and
press the “Submit” button.

Figure 3.5

Serial Screen

Type

Selects the type of interface (based on its electrical signal characteristics) used
by the equipment connected to the Serial port.

Values: V.35, RS-232, EIA-530
Default: V.35

NOTICE:

V.35 requires the use of an optional cable. Refer to "Optional
Equipment" on page A-4 f
or ordering information.

Button

Function

Submit

Sets any values that have been changed.

Clear Alarms

Resets the alarm conditions and counts to zero.

Network Services

Displays the Services screen for the Network interface.

Refresh

Refreshes data on the current page.