Status and alarms table, Status and alarms table -19 – Verilink WANsuite 5330 (34-00302.F) Product Manual User Manual
Page 47
![background image](https://www.manualsdir.com/files/808571/content/doc047.png)
W e b S e r v e r I n t e r f a c e
3-19
Round Trip Delay Rate
Specifies the rate (in seconds) at which Round Trip Delay packets are sent.
Status and Alarms Table
The table displayed at the bottom of the Frame Relay Service Details screen
reports on the status and condition of LMI parameters and on Receive/
Transmit alarms and thresholds. Alarm threshold levels may be changed by
entering a new threshold value in the appropriate field of the table and
clicking the “Submit” button. Table fields are described below.
Active
Read-only field shows whether or not (Yes or No) an alarm is active.
LMI Type
Read-only status indicates ANSI, CCITT, LMI rev. 1, or Unknown.
FrameStart Status
Read-only status indicates Sourcing, Monitoring, or 0.
Rx Invalid Threshold
Number of invalid frames received during a 15-minute interval after which an
invalid alarm will be triggered. Default of “0” disables this alarm.
Rx Invalid Alarm
Status of this alarm indicates OK or Alarmed.
Tx Threshold
Number of bits per second sent during a 15-minute interval after which a Tx
alarm will be triggered. Default of 0 disables this alarm.
Tx Alarm
Status of this alarm indicates OK or Alarmed.
Rx Threshold
Number of bits per second sent during a 15-minute interval after which an Rx
alarm will be triggered. Default of 0 disables this alarm.
Rx Alarm
Status of this alarm indicates OK or Alarmed.
The Frame Relay Service Details screen provides the following user-activated
buttons:
NOTICE:
When a “Submit” is executed, the Frame Relay link will be re-
initialized with the new parameters, causing a brief interruption in data
transfer.
Button
Function
Submit
Sets any values that have been changed.
Frame Relay Statistics Opens the Frame Relay Statistics screen for the current Frame
Relay service.
DLCI Table
Opens the DLCI Table screen, which displays all the DLCIs
on the current service. Refer to DLCI Table Screen on
page 3-35 for more information.
Clear Alarms
Clears all Frame Relay alarms.
Refresh
Refreshes data on the current page.