Overview
Verilink QUAD T1 User Manual
1-3
Usually the
LOCAL
port is not used. Instead, the module is managed
through the SCM.
shows the front panel of the QUAD T1
module.
Figure 1-1 QUAD T1 Front Panel
LEDs
The front panel has five Light Emitting Diodes (LEDs).
SYS LED
The possible states for the SYS (System) led are shown in
Table 1-1
System LED States
Port LEDs
The port LEDs reflect the conditions listed in
Table 1-2
Port LED States
QUAD
T1
1
2
SYS
4
3
LOCAL
PORT
PORT
PRI
EXT
MANAGEMENT
LED State
Indication
Off
No power to the module.
Steady Green
Power and the module is not the shelf controller. This is typical.
Blinking Green to Off
Power and the module is the shelf controller, should not occur with an SCM present
in the node.
Amber
Shelf master negotiation is in progress. Normal during power-up cycle.
LED State
Indication
Off
The port is not in service. See
.
Solid Green
The port is in service with no alarms or loopbacks.
Solid Red
The port is in service with one or more major alarms.
Solid Amber
The port is in service and a loopback or test is in effect, or a yellow alarm (RAIS) is
being received.
Blinking Amber to
Red
The port is in service, a loopback or test is in progress, and errors are detected.