Error events, Reset performance registers, Standard 24 hour – Verilink PRISM 3060-10 (34-00252.4) Product Manual User Manual
Page 52: Status, Completed days, Completed intervals, 24 hr.% error free, Performance data), User, Telco

44
T
ERMINAL
O
PERATION
USER NET.
Display the user performance registers for the network.
USER DTE.
Display the user performance registers for the T1 DTE.
TELCO NET.
Display the telco performance registers for the network.
TELCO DTE.
Display the telco performance registers for the T1 DTE.
Error
Events
Displays the running total of ESF error events for the circuit selected in
Element
and is applicable only when
Target
is set to
USER
. This count accumulates until it
reaches 65535 or is reset by pressing Enter with the (
RESET
) field highlighted.
Reset
Performance
Registers
Allows the element registers to be reset and may only be used when the
Target
field is set to
USER
. If Enter is pressed, the following warning appears:
DELETE ALL PERFORMANCE DATA?
(NO!)
(YES)
To exit this screen without performing the reset function, press Enter with
NO
selected. To proceed with the reset function, press Enter on YES. All values for the
chosen register set (NET or DTE) are then reset to zero.
Standard
24 Hour
Toggling this field with the spacebar steps through the four available performance
screens.
The remainder of the fields in the Performance screen are for display only. They
are defined as follows.
Status
Displays the selected T1 line status derived from the type (or absence) of errors in
the received data. This status represents the immediate state of the received T1
signal and is not related to the alarm thresholds. This field shows one or more of
the signal conditions listed in Table 4-3.
Completed Days
Displays the number of days included in the 30 -day totals.
Completed Intervals
Displays the number of 15 -minute intervals in the last 24 -hour period since the
registers were last cleared (a 24- hour period may contain up to 96 intervals).
24 Hr. % Error Free
Displays the percentage of error-free seconds within the last 24 hours or since the
event registers were last cleared. It is based only on the ES and UAS parameters.
(Performance data)
The main body of display data consists of error events for three different
periods: The first display line shows the data accumulated for the current interval
(from 0 to 900 seconds). The second line shows the totals for the last 24 -hour
period (or the last 96 fifteen-minute intervals). The third line shows the 30 -day
totals.