DSU MP Specifications

3

Environmental

Operating Temp:

0

°

to 50

°

C (32

°

to 122

°

F)

Storage Temp:

-20

°

to 85

°

C (-4

°

to 185

°

F)

Humidity:

95% maximum (non -condensing)

Compatibility

TR 62411:

December 1990

TR 41458:

April 1990 (where applicable)

TR 54016:

September 1989

T1.403:

1989

TR 54019A:

April 1988

Industry

Listings

FCC Compliance:

Part 15 Subpart B, Class A, Part 68

Industry Canada:

CS03

US Safety:

UL1459, 2nd Edition

Canadian Safety:

CSA C22.2, No. 225-M90

DSU MP
Specifications

DDS I Port
Data Rate

Sync:

56 kbps

TXP I Port

Data Rates

NON-TDM:

Async:

2.4, 4.8, 9.6, 19.2, 38.4, 52, and 57.6 kbps

Sync:

2.4, 4.8, 9.6, 19.2, 38.4, and 52 kbps

TDM:

Async:

2.4, 4.8, 9.6, 19.2, and 31.2 kbps*

Sync:

2.4, 4.8, 9.6, 19.2, and 31.2 kbps*

DDS II Port

Data Rate

Sync:

64 kbps

TXP II Port

Data Rates

NON-TDM:

Async:

2.4, 4.8, 9.6, 19.2, 38.4, 56, 57.6, and 60 kbps

Sync:

2.4, 4.8, 9.6, 19.2, 38.4, 56, and 60 kbps

TDM:

Async:

2.4, 4.8, 9.6, 19.2, and 38.4 kbps*

Sync:

2.4, 4.8, 9.6, 19.2, and 38.4 kbps*

* Only one port (A or B) can be set to the highest rate at any given time. For

example, if Port A is set to the highest rate, Port B can be set no higher than the
next highest rate.

Configuration

Configuration:

Front panel LCD, terminal interface on supervisory port,
telnet session through the TXPORT 8100A Site Controller.

SNMP management through the TXPORT 8100A Site
Controller.

Soft configuration is non-volatile.