The Alarms screen (Figure 4-4) allows viewing the alarm status of the network and
the DTE lines. The DTE Alarms field is described as follows.
NET Alarms
These status lines display the selected element’s current network /DTE signal alarm
state. Alarms are determined by the user-selectable thresholds listed in Table 4-2.
3060 DSU x.xx/x.xx
PRISM 3060
Date: MM/DD/YY
3060 DSU x.xx/x.xx
TXPORT Prism 3060-10
Time: HH:MM:SS
----------------------------------- ALARMS -------------------------------------
Element: [ ]
NET Alarms: NONE
DTE Alarms: OK
Current Threshold
Loss of Signal Seconds (LOSS) 0 5
Errored Seconds (ES) 2 45
Severely Errored Seconds (SES) 2 5
Unavailable Seconds (UAS) 0 0
Out of Frame Seconds (OOFS) 0 5
Remote Alarm Seconds (RAS) 0 0
AIS Seconds (AISS) 0 0
BPV Seconds (BPVS) 0 0
DTE LOS/OOF Seconds (LOSS) 0 0
Power Loss Seconds (PLS) 0 0
Reset Alarm Registers (RESET)
------------------------------------Messages------------------------------------
Local Screen
igure 4-4 Alarms Screen
Table 4-2 Alarm Indications
Alarm
Description
NONE
No alarm threshold has been exceeded, although
errors may exist that do not exceed thresholds.
ERRS
The Errored Seconds, Severely Errored Seconds, or
Bipolar Errored Seconds threshold is exceeded.
LOSS
The Loss Of Signal Seconds threshold is exceeded.
OOFS
The Out Of Frame Seconds threshold is exceeded.
RAIS
The Remote Alarm Seconds threshold is exceeded.
AISS
The Alarm Indication Seconds threshold is exceeded.
UAS
The Unavailable Seconds threshold is exceeded.