T1net configuration, Framing type, Line code – Verilink PRISM 3060-10 (34-00252.4) Product Manual User Manual
Page 27: Line build out, Timing, Internal, Network, Station, T1 net configuration, Framing type line code line build out timing

T1 NET Configuration
19
T1 NET
Configuration
The T1 NET Configuration screen (Figure 3-8) allows setting the following
network configuration parameters.
Defaults are shown underlined.
Framing Type
Selects the framing for the T1 network. The choices are D4 and ESF.
Line Code
Sets the network side line coding. The choices are AMI and B8ZS.
Line Build Out
Sets the line build out for the network interface. The choices are 0 dB, -7.5 dB,
-15 dB, and -22.5 dB.
Timing
Sets the timing source to synchronize the unit’s internal timing generators. In all
cases, slips are controlled to occur on frame boundaries at the network and /or
DSX1 ports when timing synchronization is lost. The choices are as follows.
INTERNAL
The unit’s internal frequency standard is used for all timing.
NETWORK
Timing is derived from the network-recovered clock (the most common selection
for most applications).
STATION
Timing is derived from a bipolar- or TTL-compatible clock supplied to the unit
through the rear panel. This field shows the input timing and only appears when
✍
Figure 3-7 T1 NET Configuration Menu
Framing
Type
Line
Code
Line
Build
Out
Timing
ESF
D4
AMI
B8ZS
0 dB
- 7.5 dB
-15 dB
-22.5 dB
Internal
Network
T1 DTE
Station
Slot X / Port Y,
(where
X = 3 to 6 and
Y = A or B)
Station
Input
Timing
1.544
MHz
N
×
56 K
N
×
64 K
(Station
Timing
must be
selected)
Zero
Suppress
Enable
Disable
PRM
Enable
Enable
Disable
Alarm
Thresholds
Station
Timing
Selects the
N
multiplier
(1 - 24)
for the
Input
Timing.
Alarm Reset 030
ES 045
SES 005
LOSS 005
OOFS 005
UAS 000
RAS 000
AISS 000
BPVS 000
T1 NET Configuration
Line Code .............
AMI
<