Date, User info/unit id, Nms address – Verilink PRISM 3060-10 (34-00252.4) Product Manual User Manual
Page 41: Nms bit rate, Supv bit rate, Boot mode, Alarm cutoff, Call on alarm, Alarm notification

System Utilities
33
Date
The current date is set by entering each digit in the standard
MM/DD/YY
date
format. Each field is range checked and automatically limited to the appropriate
range of values.
User
Info/Unit
ID
The idle screen top line may be changed in this field. Text is entered using the up
and down arrow keys to scroll through each character and the right arrow key to
change cursor position. The original text can be restored by pressing Exit at any
time during the editing process. The screen is shown in Figure 3-18.
NMS
Address
When used with the TXPORT 8100A Site Controller, each unit connected to the
local daisy chain must be programmed with a unique address in the range of
1
through
63
. To program a number, scroll through the digits with the up and down
arrow key. Press the right arrow key to select a digit. A valid NMS address must
be selected before the configuration can be recalled upon start up.
After software has been downloaded into the flash memory, the RAM must be
cleared. This process sets the NMS address to
251
.
NMS
Bit Rate
Sets the interface speed for the
NMS
IN
and
NMS
OUT
ports. The selections are
1200
,
2400
,
4800
,
9600
, and
19200
bps.
Supv
Bit Rate
Sets the interface speed for the supervisory port (
SUPV
). The selections are
1200
,
2400
,
4800
,
9600
, and
19200
bps.
Boot
Mode
When the unit is powered, configuration is based on this selection. If set to
LOCAL
, the unit restores the configuration parameters in effect when power was
lost. If set to
NMS
, the unit uses the configuration parameters supplied from the
EM8000 element manager database (the unit must have a valid NMS address: from
1 to 250). As shipped from the factory, the unit uses the factory default
configurations stored in the
LOCAL
memory.
Alarm
Cutoff
When this menu item is set to
DISABLE
, the unit reports a network interface alarm
condition by lighting the front panel indicator and activating the alarm relay
contacts on the rear panel. When set to
ENABLE
, the front panel
ALARM
indicator
still lights during an alarm condition, but the alarm contacts are forced to an
inactive state regardless of the alarm status.
Call on
Alarm
Controls remote alarm reporting. Three submenus are available as follows.
Alarm Notification
OFF.
Disables alarm reporting.
TXPORT PRISM 3060
/ =Letter
Select=Done
= move
Figure 3-18 User Info/Unit ID Display Screen