Super Systems 9120 with TS User Manual
Page 20

SSi 9120 Touchscreen Interface
4586 – 9120 With Touch Screen Interface
Page 20 of 80
Subnet Mask
This option will allow the user to modify the IP subnet mask of the
9120 Instrument
only. The
address must be supplied in a 999.999.999.999 format, or it will not be accepted. Contact Super
Systems at 800-666-4330 or your IT department before changing any of the IP addresses.
Gateway
This option will allow the user to modify the IP gateway of the
9120 Instrument
only. The
address must be supplied in a 999.999.999.999 format, or it will not be accepted. Contact Super
Systems at 800-666-4330 or your IT department before changing any of the IP addresses.
Furnace Setup
This screen will allow the user to
configure the furnace settings. Do not
make any adjustments on this screen
without first contacting Super Systems
Inc at 800-666-4330.
Date and Time
This option will allow the user to
change the current date and time
on
the 9120 controller
, not the touch
screen.
The date and time that is
recorded on the flash card (and,
therefore, the datalog data) is the
date and time of the Advantech
display, not the 9120 instrument.
To change the date and time of
the touch screen, see
Appendix B
– Changing the Date/Time on the Touchscreen.
Note – The initial date and time displayed
will be the system time of the Touchscreen, not the current time on the 9120 instrument
.
PVT Type
The PVT type is the mode the device runs in (Carbon, Dewpoint, etc.). The mode selected
determines the calculations and scaling for the Process Variable.
The values for the PVT type are:
Carbon
Dew Point
Oxygen
Millivolt
Redundant Probe
Simple Nitrider
Dual Loop
Temperature
This value determines the specific temperature scale to be used. Clicking on the value will allow
the operator to change the value. It can be either Degrees
°°°°
F or degrees
°°°°
C.
Web Level 1 Code