Group 2 - Timers

Timer settings are used to configure a number of timer events on the PixiePro.

Note: To deactivate any timer, set the timer value to 0-0.

Setting 1 - Automatic Shutdown Timer (off = 0-0, level = 0-1 through 3-7)
The PixiePro may be set to automatically send the power off command if the user does not make a
button press after a configurable length of time. This may be used to prevent users from accidentally
leaving projectors running overnight. Requires use of the discrete power on/off button module.
Default: 0-0 (off)

Setting 2 - Warm Up Display Timer (off = 0-0, level = 0-1 through 3-7)
The Warm Up Display Timer may be configured to signal the user that the display device is warming
up for a specified length of time (see the Timer Configuration Values Table on page 23). The
PixiePro will illuminate the hourglass status LED for the duration of the Warm Up Display Timer after
the Power On button is pressed. Enabling this setting requires use of the discrete power on/off but-
ton module.
Default: 0-0 (off)

Setting 3 - Cool Down Display Timer (off = 0-0, level = 0-1 through 3-7)
The Cool Down Display Timer may be configured to signal the user that the display device is warm-
ing up for a specified length of time (see chart below). The PixiePro will illuminate the hourglass sta-
tus LED for the duration of the Cool Down Display Timer after the Power Off button is pressed.
Requires use of the discrete power on/off button module.
Default: 0-0 (off)

Setting 4 - Security Retry Lockout Timer (off = 0-0, level = 0-1 through 3-7)
The PixiePro may be set to undergo a configurable-length delay after unsuccessful attempts to
unlock the interface. This will discourage attempts to guess security codes.
Default: 0-0 (off)

Example 1 - Setting the Automatic Shutdown Timer: Press Aux 2 to select the Timer Settings
group. Press Source 1 to select the Automatic Shutdown Timer settings. Use Volume Up/Volume
Down buttons to select a value between 0-0 and 3-7. Once the appropriate selection has been
made, press any power button to accept selection. See the Timer Configuration Values Table on
page 23 for examples of the various settings.

22