beautypg.com

SP Controls PixiePro User Manual

Page 24

background image

Configuration Setting Descriptions

Group 1 - Core Functions

Core function settings determine behavior of PixiePro.

Setting 1 - Multiple-Device TCM Mode (toggle)
Enable this setting to allow the TCM to control multiple devices. Disable to always control a single
device with the TCM module. See Section IX Operation for more information.
Default: Enabled (Multiple-Device Mode)

Setting 2 - “Device 0” on TCM in Multiple-Device Mode (toggle)
The TCM may switch to a device 0 profile when the currently selected Source button is pressed
again. This allows users to always access a desired code set regardless of which source is currently
selected. See Programming the Transport Control/Menu Module on page 15 for more information.
Default: Disabled

Setting 3 - Input Selection Lights on TCM Persist in Single-Device Mode (toggle)
When the TCM on the PixiePro has been configured to be in Single-Device mode, enabling this set-
ting will cause the most recently pressed input selection light to become brighter after being
pressed. Having this setting disabled will cause the lighting on the input selection buttons to remain
constant while in Single-Device mode, regardless of which button was most recently pressed.
Default: Disabled

Setting 4 - Defeat In-Progress Macro on Button Press (toggle)
When enabled, pressing a button while the PixiePro is in the process of sending a macro will dis-
card the remainder of the macro being sent and send the new code. When disabled, buttons
pressed while the PixiePro is sending a macro will have no effect.
Default: Disabled

Setting 5 - Fixed-Length Code Learning (range of 0-0 through 3-7, 0-0 is lowest setting)
When the PixiePro learns a code, this value determines how many repetitions of the code the
PixiePro will record. When the code is sent as part of a macro, this will determine the length the
PixiePro will send the code for in a single send. When the PixiePro sends this button independently,
this value will not affect how long it is sent, unless Setting 6 is enabled.
Default: 0-1

Setting 6 - Fixed-Length Code Learning Applies to Single-Code Learning (toggle)
When this setting is enabled, the code duration recorded during learning (configurable in Setting 6
above) will be the minimum-length send for any code. This will prevent the user from inadvertently
pressing a button for too short a time t o control the device.
Default: Enabled

Setting 7 - High-Frequency Carrier Default (toggle)
When enabled, the PixiePro will assign a 455 kHz carrier frequency to an IR signal if it does not
detect a carrier frequency. SP Controls recommends that this setting remain enabled (default).
Default: Enabled

21