Sloan EW-62000 Installaton User Manual
Page 7
7
8B
Install Batteries (Models EW-
62050 / EW-63050 Only)
A
Loosen Cover
Screws and
remove Cover
from Control
Module.
B
Remove Battery Compartment and install four (4) AA-size
batteries (supplied) as indicated by the (+) and (-) symbols
inside the Battery Compartment.
C
Reinstall Battery Compartment into the Control Module. Make
sure that the electrical contacts are facing up.
D
Reinstall Control Module Cover using all four (4) Screws.
11
Test Faucet Operation
A
Place hands under spout. Solenoid valve should “click”, LED in
sensor window should blink once and water should flow from
the spout.
B
Release the red button when the sensor starts flashing.
9
Set Range Adjustment
10
Set Water Flow Time-Out
A
Hold the red button in for more than six (6) seconds. The water
flow time-out settings will change from 7 seconds to 70
seconds or from 70 seconds to 7 seconds.
B
When hands are removed, the water flow should stop.
Note: Sensor Range can be adjusted after power is supplied to the
Faucet (battery or hardwire).
Note: The Sensor range
is dependent on the
distance of your hand or
card while the sensor is
in range setting mode.
Note: If no target is placed in front of the sensor, the sensor range will
set to its longest distance.
Note: There are two available time-out settings: 7 seconds and 70
seconds.
ELECTRICAL CONTACTS
MUST BE FACING UP
E
Turn on Water as instructed in D and E of Step 8A.
A
Press and hold the red button for 3-6
seconds. When the button is first pressed,
the water turns on. At 3 seconds, the
sensor (beneath spout) starts
flashing and the water
stops flowing.
C
Place your hand (or card) in front of the sensor at the distance
you desire the faucet to activate. Keep hand (or card) at the
sensing distance while the sensor range is setting and the
sensor is flashing.
D
Remove hand (or card) when the
sensor stops flashing. The
sensor range is now set.