Sloan 110 Royal Exposed Flushometer User Manual
Installation instructions for exposed royal, Flushometers, Prior to installation rough-ins
Code No. 0816195
Rev. 6 (02/15)
INSTALLATION INSTRUCTIONS FOR EXPOSED ROYAL
®
FLUSHOMETERS
LIMITED WARRANTY
Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship
for a period of three (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of first purchase. During this period, Sloan Valve
Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole
and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at customer’s cost. No claims will be allowed for labor, transportation or other costs.
This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does
not cover the life of the batteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY
RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
Before you install the flushometer, be sure the items listed below are
installed. Also, refer to the rough-in diagram below.
• Closet fixture • Drain line • Water supply line
IMPORTANT:
• ALL PLUMBING SHOULD BE INSTALLED IN
ACCORDANCE WITH APPLICABLE CODES AND
REGULATIONS.
• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE
AN ADEQUATE VOLUME OF WATER FOR EACH
FIXTURE.
• FLUSH ALL WATER LINES PRIOR TO MAKING
CONNECTIONS.
Sloan’s flushometers are designed to operate with 15 to 80 psi (103
to 552 kPa) of water pressure.
THE MINIMUM PRESSURE
REQUIRED TO THE VALVE IS DETERMINED BY THE
TYPE OF FIXTURE SELECTED. Consult fixture manufacturer for
minimum pressure requirements. Most High Efficiency water closets require
a minimum flowing pressure of 25 psi (172 kPa). Many building codes and
the ASME A112.19.2 fixture standard list Maximum static water pressure as
80 PSI (552 kPa).
Urinal Flushometer
for 1¼” Top Spud
MODEL 180
Urinal Flushometer
for ¾” Top Spud
MODEL 186
Closet Flushometer
for 1½” Top Spud
MODELS 110/111,
113, 115 & 116
Service Sink Flushometer
for 1½” Top Spud
MODEL 117
MODELS 110/111,
113, 115, & 116
MODELS 180/186
MODEL 117
Closet Flushometer
for 1½” Back Spud
MODELS 120, 121 & 122
PRIOR TO INSTALLATION
ROUGH-INS
MODELS 120, 121, & 122
MODEL 186
WHEN MOUNTED ON AN ADA ACCESSIBLE BOWL, THE ROUGH-IN TO
THE SUPPLY INLET SHOULD BE NO HIGHER THAN 37½” OR THE
HANDLE WILL EXCEED MAXIMUM HEIGHT ALLOWANCES UNDER ADA
GUIDELINES.
!!! IMPORTANT !!!
- 111 Royal Exposed Flushometer 113 Royal Exposed Flushometer 115 Royal Exposed Flushometer 116 Royal Exposed Flushometer 117 Royal Exposed Flushometer 180 Royal Exposed Flushometer 186 Royal Exposed Flushometer 120 Royal Exposed Flushometer 121 Royal Exposed Flushometer 122 Royal Exposed Flushometer 111 UPPERCUT Flushometer 113 UPPERCUT Flushometer 115 UPPERCUT Flushometer 116 UPPERCUT Flushometer 120 UPPERCUT Flushometer 601 Prison Flushometer 603 Prison Flushometer 611 Prison Flushometer 681 Prison Flushometer 609 Prison Flushometer 613 Prison Flushometer 9603 Prison Flushometer 9609 Prison Flushometer 9613 Prison Flushometer 110 Sloan Exposed Flushometer 111 Sloan Exposed Flushometer 113 Sloan Exposed Flushometer 115 Sloan Exposed Flushometer 116 Sloan Exposed Flushometer 117 Sloan Exposed Flushometer 180 Sloan Exposed Flushometer 186 Sloan Exposed Flushometer 120 Sloan Exposed Flushometer 121 Sloan Exposed Flushometer 122 Sloan Exposed Flushometer