INSTALLATION INSTRUCTIONS FOR EXPOSED ROYAL

®

FLUSHOMETERS

LIMITED WARRANTY

Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship

for a period of three (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of first purchase. During this period, Sloan Valve

Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole

and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at customer’s cost. No claims will be allowed for labor, transportation or other costs.

This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does

not cover the life of the batteries.

THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY

RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.

Before you install the flushometer, be sure the items listed below are

installed. Also, refer to the rough-in diagram below.
• Closet fixture • Drain line • Water supply line

IMPORTANT:

• ALL PLUMBING SHOULD BE INSTALLED IN

ACCORDANCE WITH APPLICABLE CODES AND

REGULATIONS.

• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE

AN ADEQUATE VOLUME OF WATER FOR EACH

FIXTURE.

• FLUSH ALL WATER LINES PRIOR TO MAKING

CONNECTIONS.

Sloan’s flushometers are designed to operate with 15 to 80 psi (103

to 552 kPa) of water pressure.

THE MINIMUM PRESSURE

REQUIRED TO THE VALVE IS DETERMINED BY THE

TYPE OF FIXTURE SELECTED. Consult fixture manufacturer for

minimum pressure requirements. Most High Efficiency water closets require

a minimum flowing pressure of 25 psi (172 kPa). Many building codes and

the ASME A112.19.2 fixture standard list Maximum static water pressure as

80 PSI (552 kPa).

Urinal Flushometer

for 1¼” Top Spud

MODEL 180

Urinal Flushometer

for ¾” Top Spud

MODEL 186

Closet Flushometer

for 1½” Top Spud

MODELS 110/111,

113, 115 & 116

Service Sink Flushometer

for 1½” Top Spud

MODEL 117

MODELS 110/111,

113, 115, & 116

MODELS 180/186

MODEL 117

Closet Flushometer

for 1½” Back Spud

MODELS 120, 121 & 122

PRIOR TO INSTALLATION

ROUGH-INS

MODELS 120, 121, & 122

MODEL 186

WHEN MOUNTED ON AN ADA ACCESSIBLE BOWL, THE ROUGH-IN TO

THE SUPPLY INLET SHOULD BE NO HIGHER THAN 37½” OR THE

HANDLE WILL EXCEED MAXIMUM HEIGHT ALLOWANCES UNDER ADA

GUIDELINES.