beautypg.com

Sloan ETF-500 Faucet User Manual

Model etf-500, Model etf-500-s-h, Model etf-700-s-h

background image

Code No. 0816308

Rev. 2 (01/09)

INSTALLATION INSTRUCTIONS FOR

SENSOR ACTIVATED HAND WASHING FAUCETS

LIMITED WARRANTY

Sloan Valve Company warrants its ETF-500 and ETF-700 Faucets to be made of first class materials, free from defects of material or workmanship under normal use and to perform the
service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three years (1 year for special finishes) from date of
purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer's
cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or
organizations who purchase Sloan Valve Company's products directly from Sloan Valve Company for purpose of resale.

THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES
OF ANY MEASURE WHATSOEVER.

PRIOR TO INSTALLATION

Prior to installing the Sloan ETF-500 or ETF-700 Faucet, install the items
listed below. Refer to Rough-in illustrations on Page 2.
When Using Plug-In Transformer — Install electrical receptacle for plug-

in transformer (120 VAC, 2 amp service for each ETF-233
(24 VAC, 35 VA) plug-in transformer used).

When Using Box Mount Transformer — Install electrical wiring to

transformer location (120 VAC, 2 amp service for each EL-248-40
(24 VAC, 40 VA) transformer used).

• Scrub or wash-up sink
• Drain line
• Hot and cold water supply lines or tempered water supply line

Multiple Faucets

Multiple faucets can be powered by a single transformer, provided that the
transformer has been properly sized. Allow a minimum of 15 VA of current
rating for each solenoid valve used. Refer to “Step 4 — Install Transformer”
for further information.

Mixing Valve

When installing the faucet with a Sloan mixing valve, these Installation
Instructions AND the Installation Instructions packaged with the mixing valve
MUST be followed.

Important:

INSTALL ALL ELECTRICAL WIRING IN ACCORDANCE WITH

NATIONAL/LOCAL CODES AND REGULATIONS.

• INSTALL ALL PLUMBING IN ACCORDANCE WITH APPLICABLE CODES

AND REGULATIONS.

• A 24 VAC STEP-DOWN TRANSFORMER MUST BE USED.
• USE APPROPRIATE PRECAUTIONS WHILE CONNECTING TRANSFORMER

TO 120 VAC POWER SOURCE.

• DO NOT PLUG TRANSFORMER INTO POWER SOURCE (RECEPTACLE)

UNTIL ALL WIRING IS COMPLETED. ALLOWING 24 VAC TRANSFORMER
WIRES TO TOUCH OR SHORT WHILE POWER IS BEING SUPPLIED WILL

CAUSE PERMANENT DAMAGE TO THE TRANSFORMER AND CIRCUIT
CONTROL MODULE.

• KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT

COMPONENT PART DAMAGE! DO NOT USE ANY SEALANT ON
COMPRESSION FITTINGS. FOR THREADED PIPE FITTINGS, DO NOT APPLY
SEALANT TO THE FIRST TWO “STARTER” THREADS.

• FLUSH ALL WATER LINES UNTIL WATER IS CLEAR BEFORE CONNECTING

SOLENOID TO SUPPLY STOPS.

DO NOT INSTALL THE SPRAY HEAD UNTIL AFTER THE SUPPLY
LINES HAVE BEEN FLUSHED.

FLOW RATE

The ETF-500-H and ETF-700-H Faucets with a shower spray head
incorporate a 2.2 gpm (8.3 Lpm) maximum flow control. If water flow is too
forceful, reduce flow to faucet by adjusting supply stops. If a pressure
reducing valve has been installed, adjust valve until optimum spray is
obtained. Best performance is obtained between 25 and 40 psi.

BAK-CHEK

®

TEE USAGE

When connecting the Sloan ETF-500 or ETF-700 Faucet to both hot and cold
water supplies, a Bak-Chek

®

Tee is provided and required as illustrated in the

Rough-in drawings on Page 2. Water temperature can be controlled by
adjusting the supply stops.
When connecting the faucet to a single line water supply or a pre-tempered
water supply, a Bak-Chek

®

Tee is not required.

A Bak-Chek

®

Tee is not required or provided when a Temperature Mixing

Valve is included with the faucet.

TOOLS REQUIRED FOR INSTALLATION

• Open end wrenches for hex sizes:

• Basin wrench

1/2”, 5/8”, 11/16”, 15/16”, 1-3/16”

• Slotted screwdriver, 3/16”

• Slotted screwdriver (supplied)

• Phillips head screwdriver, #2

• Pliers

• Wire stripper/crimping tool

• Pipe Wrench (ETF-500)

Model ETF-500

24 VAC, Sensor Activated

Hand Washing Faucet

With Standard Spout and Laminar

Flow Spray Head

Model ETF-500-S-H

24 VAC, Sensor Activated

Hand Washing Faucet

With Surgical Bend Spout and

Shower Spray Head

Model ETF-700-S-H

24 VAC, Sensor Activated

Hand Washing Faucet

With Surgical Bend Spout and

Shower Spray Head

Model ETF-700

24 VAC, Sensor Activated

Hand Washing Faucet

With Standard Spout and Laminar

Flow Spray Head

Compliant to: ASME A112.18.1 and CSA B125.1

Compliant to: ASME A112.18.1 and CSA B125.1

This manual is related to the following products: