Sloan ELC-41000 Installaton User Manual
Sloan For Home
![background image](https://www.manualsdir.com/files/804965/content/doc001.png)
Code No. 0816547
Rev. 1 (12/10)
INSTALLATION INSTRUCTIONS SINGLE, DOUBLE, TRIPLE AND
QUADRUPLE STATION SENSOR OPERATED
SOLID SURFACE AND BIO-DECK LAVATORY SYSTEMS
LIMITED WARRANTY
Sloan Valve Company warrants its Optima ELC-40000 Series and ELB-50000 Series Lavatory Systems to be made of first class materials, free from defects of material
or workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and
serviced, for a period of three years (1 year for special finishes) from date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace
any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole remedy available under this
warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve
Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries (for battery powered lavatory
systems).
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL
DAMAGES OF ANY MEASURE WHATSOEVER.
ELC-44000
Quadruple Station Solid Surface Lavatory System
ELC-41000
Single Station Sensor Operated
Solid Surface Lavatory System
ELC-42000
Double Station Sensor Operated
Solid Surface Lavatory System
ELC-43000
Triple Station Sensor Operated
Solid Surface Lavatory System
ELC-44000
Quadruple Station Sensor
Operated Solid Surface
Lavatory System
ELB-51000
Single Station Sensor Operated
Bio-Deck Lavatory System
ELB-52000
Double Station Sensor Operated
Bio-Deck Lavatory System
ELC-43000
Triple Station Solid Surface Lavatory System
ELC-41000
Single Station Solid Surface Lavatory System
ELC-42000
Double Station Solid Surface Lavatory System
ELB-51000
Single Station Bio-Deck Lavatory System
ELB-52000
Double Station Bio-Deck Lavatory System
Prior to installing the Sloan Optima ELC-40000 Series and ELB-50000 Lavatory
System, install the items listed below. Also, refer to the appropriate rough-in
diagram on pages 2 – 4.
• Plug-In Transformer — Install electrical receptacle(s) for plug-in
transformer(s) — 120 VAC, 2 amp service for each ETF-233 (24 VAC, 35 VA)
plug-in transformer used.
• Hot and cold water supply lines or tempered water supply line
• Drain lines
Important:
• ADEQUATE STRUCTURAL SUPPORT IN OR BEHIND THE WALL IS REQUIRED.
REFER TO THE APPROPRIATE ROUGH-IN DIAGRAM ON PAGES 2 – 4 FOR
DRY WEIGHT OF SINK. STRUCTURAL SUPPORT MUST HAVE A MINIMUM
PULLOUT RATING OF 1000 POUNDS (450 kg).
• ALL ELECTRICAL WIRING SHOULD BE INSTALLED IN ACCORDANCE WITH
NATIONAL/LOCAL CODES AND REGULATIONS.
• ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH APPLICABLE
CODES AND REGULATIONS.
• A 24 VAC STEP-DOWN TRANSFORMER MUST BE USED FOR HARDWIRE
APPLICATIONS.
• DO NOT PLUG TRANSFORMER INTO POWER SOURCE (RECEPTACLE) UNTIL
ALL WIRING IS COMPLETED. PERMANENT DAMAGE TO THE TRANSFORMER
AND CIRCUIT CONTROL MODULE WILL RESULT IF 24 VAC WIRES TOUCH
EACH OTHER OR SHORT WHEN POWER SUPPLY IS ACTIVE.
• BEFORE CONNECTING FLEX HOSES TO SUPPLY STOPS, FLUSH ALL WATER
LINES UNTIL WATER IS CLEAR.
FOR BATTERY OPERATED LAVATORY SYSTEMS, DO NOT INSTALL BATTERIES
UNTIL THE SYSTEM IS COMPLETELY INSTALLED. Installing batteries before
sensor cable is connected to control module may result in improper range
adjustment.
PRIOR TO INSTALLATION