beautypg.com

Sloan 110 Sloan Exposed Flushometer User Manual

Sloan For Home

background image

Code No. 0816558 — Rev. 3 (02/15)

INSTALLATION INSTRUCTIONS FOR EXPOSED SLOAN

WATER CLOSET AND URINAL FLUSHOMETERS

LIMITED WARRANTY

Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship for a
period of three (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of first purchase. During this period, Sloan Valve Company
will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole and exclusive
remedy under this warranty. Products must be returned to Sloan Valve Company, at customer’s cost. No claims will be allowed for labor, transportation or other costs. This warranty extends
only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries.

THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL

DAMAGES OF ANY MEASURE WHATSOEVER.

Before you install the Sloan Flushometer, be sure the items listed below are

installed. Also, refer to the rough-in diagram below.
• Closet fixture
• Drain line
• Water supply line

IMPORTANT:

• ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE

WITH APPLICABLE CODES AND REGULATIONS.

• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN

ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.

• FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.

The Sloan Flushometer is designed to operate with 15 to 80 psi (103 to 552

kPa) of water pressure. THE MINIMUM PRESSURE REQUIRED

TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE

SELECTED. Consult fixture manufacturer for minimum pressure

requirements. Most High Efficiency water closets require a minimum flowing

pressure of 25 psi (172 kPa). Many building codes and the ASME A112.19.2

fixture standard list Maximum static water presssure as 80 PSI (552 kPa).

Closet Flushometer

for 1½” Back Spud

• MODELS 120, 121 & 122

Urinal Flushometer

for 1¼” Top Spud

• MODEL 180

Urinal Flushometer

for ¾” Top Spud

• MODEL 186

Closet Flushometer for 1½”

Top Spud

• MODELS 110/111, 113, 114, 115 & 116

Service Sink Flushometer for

1½” Top Spud

• MODEL 117

PRIOR TO INSTALLATION

TOOLS REQUIRED FOR INSTALLATION

• Straight blade screwdriver
• Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed spud wrench

WITH THE EXCEPTION OF CONTROL STOP INLET, DO NOT

USE PIPE SEALANT OR PLUMBING GREASE ON ANY VALVE

COMPONENT OR COUPLING!

!!! IMPORTANT !!!

PROTECT THE FINISH OF SLOAN FLUSHOMETERS — DO

NOT USE TOOTHED TOOLS TO INSTALL OR SERVICE

THESE VALVES. USE A SLOAN A-50 SUPER-WRENCH™,

SLOAN A-109 PLIER WRENCH OR SMOOTH JAWED SPUD

WRENCH TO SECURE ALL COUPLINGS. ALSO SEE “CARE

AND CLEANING” SECTION OF THIS MANUAL.

!!! IMPORTANT !!!

THIS PRODUCT CONTAINS MECHANICAL AND/OR

ELECTRICAL COMPONENTS THAT ARE SUBJECT TO

NORMAL WEAR. THESE COMPONENTS SHOULD BE

CHECKED ON A REGULAR BASIS AND REPLACED AS

NEEDED TO MAINTAIN THE VALVE’S PERFORMANCE.

!!! IMPORTANT !!!

If you have questions about how to install your

Sloan flushometer, consult your local

Sloan Representative or call Sloan Technical Support at:

1-888-SLOAN-14 (1-888-756-2614)