PRIOR TO INSTALLATION

Prior to installing the Sloan EW-60000 Series Lavatory System, install
the items listed below. Also, refer to the appropriate rough-in diagram on
Page 2 and brackets diagram on Page 4.
• Install electrical receptacle(s) for plug-in transformer(s) — 120 VAC,

2 amp service for each SFP-36 (6 VDC, 2300 mA) plug-in transformer
used (EW-62000/EW-63000 only).

• Hot and cold water supply lines or tempered water supply line (If there

is no tempered water supply, install mechanical mixing valve between
hot and cold water supply)

• Drain lines

Important:

ADEQUATE STRUCTURAL SUPPORT IN OR BEHIND THE WALL IS

REQUIRED. REFER TO THE APPROPRIATE ROUGH-IN DIAGRAM ON
PAGE 2 FOR DRY WEIGHT OF SINK.

STRUCTURAL SUPPORT

MUST HAVE A MINIMUM PULLOUT RATING OF 1000 POUNDS

(450 Kg) FOR EACH FASTENER.

• INSTALL ALL ELECTRICAL WIRING IN ACCORDANCE WITH

NATIONAL/LOCAL CODES AND REGULATIONS.

• INSTALL ALL PLUMBING IN ACCORDANCE WITH APPLICABLE CODES

AND REGULATIONS.

• USE APPROPRIATE PRECAUTIONS WHILE CONNECTING

TRANSFORMER TO 120 VAC POWER SOURCE.

DO NOT PLUG TRANSFORMER INTO POWER SOURCE (RECEPTACLE)

UNTIL ALL WIRING IS COMPLETED.

BEFORE CONNECTING FLEX HOSES TO SUPPLY STOPS, FLUSH ALL

WATER LINES UNTIL WATER IS CLEAR.

TOOLS REQUIRED FOR INSTALLATION

• Electric drill for drilling anchor holes.
• Standard sockets and open-end wrench set for installing anchoring

fasteners and connecting water lines.

• Pipe wrench for installing drain lines.
• Phillips and straight blade screwdrivers.
• Tubing Cutter
• Level
• Carpenter’s square
• Caulk gun

SINK LOCATION
Determine the appropriate wall location for the Lavatory System.
Consider that hot and cold water supply lines, drain lines, and an
electrical source (receptacle) will be required. Compare the physical
dimensions of the Lavatory System to the space available for the
installation. If wall is not load-bearing, a carrier may be required behind
the wall. Refer to the appropriate Rough-in diagram on Page 2 for
Lavatory System dimensions.
Prior to Lavatory System installation, electric wiring, water supply and
drain must be installed.

1

Install Mechanical Mixing Valve

A

If there is no tempered water supply, install Mechanical Mixing Valve between hot and cold water supply.

MIX-60-A
MECHANICAL MIXING VALVE