Sloan 140 Royal / Regal Standard Concealed Flushometer User Manual
Sloan For Home
Check to make certain that the “L” dimension shown on the flushometer
package is correct for your application. Determine the “L” dimension for
your application by using the following formula:
“L” dimension = Wall Thickness (To Nearest Whole Inch) + 2-3/4”
Prior to installing a concealed flushometer, perform the following functions
as illustrated in the Rough-in Diagrams on Pages 2 and 3.
• Bore a 1-1/2” (38 mm) hole in wall for Actuator.
• Bore a 2” (51 mm) [1” (25 mm) for Model 197 only] hole in wall for
piping, if required.
• Install closet or urinal fixture.
• Install 1-1/2” (38 mm) drain line (NOT supplied by Sloan).
• Install water supply line. Note: Concealed valves are supplied with double
handle opening to allow for installation of Control Stop on either the left
or right side of the valve (refer to illustration in Step 4).
IMPORTANT:
• INSTALL ALL PLUMBING IN ACCORDANCE WITH
APPLICABLE CODES AND REGULATIONS.
• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN
ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.
• FLUSH ALL WATER LINES PRIOR TO MAKING
CONNECTIONS.
Sloan’s flushometers are designed to operate with 10 to 100 psi (69 to 689
kPa) of water pressure. THE MINIMUM PRESSURE REQUIRED
TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE
SELECTED. Consult fixture manufacturer for minimum pressure
requirements.
Most Low Consumption water closets (1.6 gpf/6.0 Lpf) require a minimum
flowing pressure of 25 psi (172 kPa).
Code No. 0816170
Rev. 3 (04/14)
INSTALLATION INSTRUCTIONS FOR
CONCEALED CLOSET AND URINAL FLUSHOMETERS
LIMITED WARRANTY
Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and
workmanship for a period of three (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of first purchase.
During this period, Sloan Valve Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under
normal use and service. This shall be the sole and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at customer’s cost. No claims
will be allowed for labor, transportation or other costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from
Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN
VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
Concealed Closet Flushometer —
1-1/2” Exposed Back Spud
MODEL 140
MODEL 154
Concealed Closet Flushometer —
1-1/2” Exposed Top Spud
MODEL 142
MODEL 153
Concealed Closet Flushometer —
1-1/2” Back Spud
MODEL 143
MODEL 144
MODEL 150
MODEL 152
Concealed Urinal Flushometer —
Back Spud
MODEL 190
MODEL 195
Concealed Urinal Flushometer —
Exposed Top Spud
MODEL 192
MODEL 197
Model 140
Model 195
PRIOR TO INSTALLATION
TOOLS REQUIRED FOR INSTALLATION
• Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed spud wrench
• Drill to bore 1½” (38 mm) and/or 2” (51 mm) hole(s) in wall (see rough-in)
WITH THE EXCEPTION OF CONTROL
STOP INLET, DO NOT USE PIPE THREAD
SEALANT OR PLUMBING GREASE ON VALVE
COMPONENTS OR COUPLINGS!
!!! IMPORTANT !!!