MODEL 9603 – WATER CLOSET

1” I.P.S.

SUPPLY

(25 mm DN)

CENTER LINE

OF FIXTURE

4-3/4”

(121 mm)

CENTER LINE

OF WASTE

FIN.

FLOOR

FIN. WALL

3-1/4” (83 mm)

LONG FLUSH TUBE

(FOR CONNECTION

BEHIND WALL)

PUSH BUTTON

(TYPE AND

LOCATION

OPTIONAL)

16”

(406 mm)

14-1/2”

(368 mm)

1” I.P.S.

SUPPLY

(25 mm DN)

CENTER LINE

OF FIXTURE

CENTER LINE

OF WASTE

FIN.

FLOOR

1-1/2” (38 mm)

OPENING

IN WALL

16”

(406 mm)

14-1/2”

(368 mm)

4-3/4”

(121 mm)

3-1/4” (83 mm)

LONG FLUSH TUBE

(FOR CONNECTION

BEHIND WALL)

MODEL 9609 - URINAL

MODEL 9613 – COMBINATION FIXTURE

FIN.

FLOOR

FIN. WALL

CENTER LINE

OF FIXTURE

1-1/2” (38 mm)

OPENING

IN WALL

1” I.P.S.

SUPPLY

(25 mm DN)

3-1/4” (83 mm)

LONG FLUSH TUBE

(FOR CONNECTION

BEHIND WALL)

13”

(330 mm)

3/4” I.P.S.

SUPPLY

(20 mm DN)

CENTER LINE

OF FIXTURE

1-1/2” (38 mm)

OPENING

IN WALL

12”

(305 mm)

3-1/4” (83 mm)

LONG FLUSH TUBE

(FOR CONNECTION

BEHIND WALL)

FIN.

FLOOR

FIN. WALL

14-1/2”

(368 mm)

13-1/2”

(343 mm)

4-3/4”

(121 mm)

4-3/4”

(121 mm)

PROTECT THE CHROME OR SPECIAL FINISH OF SLOAN

FLUSHOMETERS. DO NOT USE TOOTHED TOOLS TO INSTALL OR

SERVICE VALVES. USE A SLOAN A-50 SUPER WRENCH™ OR SMOOTH

jAWED SPUD WRENCH TO SECURE COUPLINGS. SEE “CARE AND

CLEANING” SECTION OF THIS MANUAL.

!!! IMPORTANT !!!

NEVER OPEN THE CONTROL STOP TO WHERE THE FLOW FROM THE

VALVE EXCEEDS THE FLOW CAPABILITY OF THE FIXTURE. IN THE

EVENT OF A VALVE FAILURE, THE FIXTURE MUST BE ABLE TO

ACCOMMODATE A CONTINUOUS FLOW FROM THE VALVE.

!!! IMPORTANT !!!

ONLY USE PIPE THREAD SEALANT WHEN INDICATED IN

THIS MANUAL. ONLY USE THE PIPE THREAD SEALANT

SUPPLIED BY SLOAN.

!!! IMPORTANT !!!

WITH THE EXCEPTION OF CONTROL STOP INLET, DO NOT

USE PIPE SEALANT OR PLUMBING GREASE ON ANY VALVE

COMPONENT OR COUPLING!

!!! IMPORTANT !!!

THIS PRODUCT CONTAINS MECHANICAL AND/OR ELECTRICAL

COMPONENTS THAT ARE SUBjECT TO NORMAL WEAR. THESE

COMPONENTS SHOULD BE CHECKED ON A REGULAR BASIS AND

REPLACED AS NEEDED TO MAINTAIN THE VALVE’S PERFORMANCE.

!!! IMPORTANT !!!

DUE TO THE HIGH BACK PRESSURES THAT CAN BE CREATED BY

STAINLESS WATER CLOSETS AND COMBINATION FIXTURES, THE

FOLLOWING PROCEDURES MUST BE FOLLOWED WHEN INSTALLING

THE FLUSH CONNECTIONS. FAILURE TO FOLLOW THESE PROCEDURES

CAN RESULT IN SEPARATIONS.

!!! IMPORTANT !!!

2-1/8” (54 mm) MIN.4-

1/8” (105 mm) MAX.

2” (51 mm) OPENING IN WALL

(1-1/2” (38 mm) CONNECTION

THROUGH WALL NOT SUPPLIED

BY SLOAN)

FIN. WALL

2” (51 mm) OPENING IN WALL

(CONNECTION THROUGH WALL

NOT SUPPLIED BY SLOAN)

2-1/8” (54 mm) MIN.4-

1/8” (105 mm) MAX.

2” (51 mm) OPENING IN WALL

(1-1/2” (38 mm) CONNECTION

THROUGH WALL NOT SUPPLIED

BY SLOAN)

2-1/8” (54 mm) MIN.4-

1/8” (105 mm) MAX.

1” (25 mm) OPENING IN WALL

(3/4” (19 mm) CONNECTION

THROUGH WALL NOT SUPPLIED

BY SLOAN)

1-1/2” (38 mm) MIN.

4-1/2” (114 mm) MAX.

PUSH BUTTON

(TYPE AND

LOCATION

OPTIONAL)

PUSH BUTTON

(TYPE AND

LOCATION

OPTIONAL)

MODEL 9603 – COMBINATION FIXTURE

ROUGH-INS (CONTINUED)