Rough-ins (continued) – Sloan 601 Prison Flushometer User Manual
Page 3
3
MODEL 9603 – WATER CLOSET
1” I.P.S.
SUPPLY
(25 mm DN)
CENTER LINE
OF FIXTURE
4-3/4”
(121 mm)
CENTER LINE
OF WASTE
FIN.
FLOOR
FIN. WALL
3-1/4” (83 mm)
LONG FLUSH TUBE
(FOR CONNECTION
BEHIND WALL)
PUSH BUTTON
(TYPE AND
LOCATION
OPTIONAL)
16”
(406 mm)
14-1/2”
(368 mm)
1” I.P.S.
SUPPLY
(25 mm DN)
CENTER LINE
OF FIXTURE
CENTER LINE
OF WASTE
FIN.
FLOOR
1-1/2” (38 mm)
OPENING
IN WALL
16”
(406 mm)
14-1/2”
(368 mm)
4-3/4”
(121 mm)
3-1/4” (83 mm)
LONG FLUSH TUBE
(FOR CONNECTION
BEHIND WALL)
MODEL 9609 - URINAL
MODEL 9613 – COMBINATION FIXTURE
FIN.
FLOOR
FIN. WALL
CENTER LINE
OF FIXTURE
1-1/2” (38 mm)
OPENING
IN WALL
1” I.P.S.
SUPPLY
(25 mm DN)
3-1/4” (83 mm)
LONG FLUSH TUBE
(FOR CONNECTION
BEHIND WALL)
13”
(330 mm)
3/4” I.P.S.
SUPPLY
(20 mm DN)
CENTER LINE
OF FIXTURE
1-1/2” (38 mm)
OPENING
IN WALL
12”
(305 mm)
3-1/4” (83 mm)
LONG FLUSH TUBE
(FOR CONNECTION
BEHIND WALL)
FIN.
FLOOR
FIN. WALL
14-1/2”
(368 mm)
13-1/2”
(343 mm)
4-3/4”
(121 mm)
4-3/4”
(121 mm)
PROTECT THE CHROME OR SPECIAL FINISH OF SLOAN
FLUSHOMETERS. DO NOT USE TOOTHED TOOLS TO INSTALL OR
SERVICE VALVES. USE A SLOAN A-50 SUPER WRENCH™ OR SMOOTH
jAWED SPUD WRENCH TO SECURE COUPLINGS. SEE “CARE AND
CLEANING” SECTION OF THIS MANUAL.
!!! IMPORTANT !!!
NEVER OPEN THE CONTROL STOP TO WHERE THE FLOW FROM THE
VALVE EXCEEDS THE FLOW CAPABILITY OF THE FIXTURE. IN THE
EVENT OF A VALVE FAILURE, THE FIXTURE MUST BE ABLE TO
ACCOMMODATE A CONTINUOUS FLOW FROM THE VALVE.
!!! IMPORTANT !!!
ONLY USE PIPE THREAD SEALANT WHEN INDICATED IN
THIS MANUAL. ONLY USE THE PIPE THREAD SEALANT
SUPPLIED BY SLOAN.
!!! IMPORTANT !!!
WITH THE EXCEPTION OF CONTROL STOP INLET, DO NOT
USE PIPE SEALANT OR PLUMBING GREASE ON ANY VALVE
COMPONENT OR COUPLING!
!!! IMPORTANT !!!
THIS PRODUCT CONTAINS MECHANICAL AND/OR ELECTRICAL
COMPONENTS THAT ARE SUBjECT TO NORMAL WEAR. THESE
COMPONENTS SHOULD BE CHECKED ON A REGULAR BASIS AND
REPLACED AS NEEDED TO MAINTAIN THE VALVE’S PERFORMANCE.
!!! IMPORTANT !!!
DUE TO THE HIGH BACK PRESSURES THAT CAN BE CREATED BY
STAINLESS WATER CLOSETS AND COMBINATION FIXTURES, THE
FOLLOWING PROCEDURES MUST BE FOLLOWED WHEN INSTALLING
THE FLUSH CONNECTIONS. FAILURE TO FOLLOW THESE PROCEDURES
CAN RESULT IN SEPARATIONS.
!!! IMPORTANT !!!
2-1/8” (54 mm) MIN.4-
1/8” (105 mm) MAX.
2” (51 mm) OPENING IN WALL
(1-1/2” (38 mm) CONNECTION
THROUGH WALL NOT SUPPLIED
BY SLOAN)
FIN. WALL
2” (51 mm) OPENING IN WALL
(CONNECTION THROUGH WALL
NOT SUPPLIED BY SLOAN)
2-1/8” (54 mm) MIN.4-
1/8” (105 mm) MAX.
2” (51 mm) OPENING IN WALL
(1-1/2” (38 mm) CONNECTION
THROUGH WALL NOT SUPPLIED
BY SLOAN)
2-1/8” (54 mm) MIN.4-
1/8” (105 mm) MAX.
1” (25 mm) OPENING IN WALL
(3/4” (19 mm) CONNECTION
THROUGH WALL NOT SUPPLIED
BY SLOAN)
1-1/2” (38 mm) MIN.
4-1/2” (114 mm) MAX.
PUSH BUTTON
(TYPE AND
LOCATION
OPTIONAL)
PUSH BUTTON
(TYPE AND
LOCATION
OPTIONAL)
MODEL 9603 – COMBINATION FIXTURE
ROUGH-INS (CONTINUED)
- 603 Prison Flushometer 611 Prison Flushometer 681 Prison Flushometer 609 Prison Flushometer 613 Prison Flushometer 9603 Prison Flushometer 9609 Prison Flushometer 9613 Prison Flushometer 111 UPPERCUT Flushometer 113 UPPERCUT Flushometer 115 UPPERCUT Flushometer 116 UPPERCUT Flushometer 120 UPPERCUT Flushometer