MODELS 601 & 603

MODEL 611

MODEL 681

AFD VARIATION

If the valve installation includes an Anti-Flood Device installed between the valve
body and the vacuum breaker, the valve must be ordered with the “AFD” variation.
This assures that the proper length Vacuum Breaker tube is supplied. Anti-Flood
Device is supplied by the fixture manufacturer. Consult the fixture manufacturer
for installation requirements.
† Check that the “L” dimension shown on the flushometer package is correct

for your application. Determine the “L” dimension for your application by
using the following formula:
For Models 609, 611 and 613 – “L” Dim. = wall thickness (measured to

nearest whole inch) + 2-3/4” (70 mm)
For Models 601 and 603 – “L” Dim. = wall thickness (measured to nearest

whole inch) + 4-3/4” (121 mm)
For Model 681 – “L” Dim. = wall thickness (measured to nearest whole inch)

+ 6-3/4” (171 mm)

‡ For Solenoid Activated Flushometers (ES and ESM variations), the Water

Supply Rough-in dimension is 16” (406 mm).

MODEL 609

MODEL 613

“L” DIM

4-3/4” (121 mm)

+ WALL THICKNESS

CENTER LINE

OF FIXTURE

1-1/2” (38 mm)

OPENING

IN WALL

1” I.P.S.

SUPPLY

(25 mm DN)

FIN.

FLOOR

CENTER LINE

OF WASTE

FIN. WALL

2” (51 mm) OPENING IN WALL

(1-1/2” (38 mm) CONNECTION

THROUGH WALL NOT SUPPLIED

BY SLOAN)

3-1/4” (83 mm)

LONG FLUSH TUBE

(FOR CONNECTION

BEHIND WALL)

2-1/8” (54 mm) MIN.4-

1/8” (105 mm) MAX.

4-3/4”

(121 mm)

FIN.

FLOOR

FIN. WALL

CENTER LINE

OF WASTE

CENTER LINE

OF FIXTURE

4-3/4”

(121 mm)

1-1/2” (38 mm)

OPENING

IN WALL

3-1/4” (83 mm)

LONG FLUSH TUBE

(FOR CONNECTION

BEHIND WALL)

1” I.P.S.

SUPPLY

(25 mm DN)

22-1/2”

(572 mm)

FIN.

FLOOR

FIN. WALL

1-1/2” (38 mm)

OPENING

IN WALL

CENTER LINE

OF FIXTURE

4-3/4”

(121 mm)

1” I.P.S.

SUPPLY

(25 mm DN)

3-1/4” (83 mm)

LONG FLUSH TUBE

(FOR CONNECTION

BEHIND WALL)

13”

(330 mm)

4-3/4”

(121 mm)

3/4” I.P.S.

SUPPLY

(20 mm DN)

CENTER LINE

OF FIXTURE

1-1/2” (38 mm)

OPENING

IN WALL

12”

(305 mm)

3-1/4” (83 mm)

LONG FLUSH TUBE

(FOR CONNECTION

BEHIND WALL)

FIN.

FLOOR

FIN. WALL

CENTER LINE

OF FIXTURE

4-3/4”

(121 mm)

1” I.P.S.

SUPPLY

(25 mm DN)

1-1/2” (38 mm)

OPENING

IN WALL

FIN.

FLOOR

CENTER LINE

OF WASTE

FIN. WALL

3-1/4” (83 mm)

LONG FLUSH TUBE

(FOR CONNECTION

BEHIND WALL)

26”

(660 mm) ‡

MODEL 601

20-1/2”

(521 mm)

MODEL 603

16”

(406 mm)

MODEL 601

19” (483 mm)

MODEL 603

14-1/2”

(368 mm)

24”

(610 mm)

2-1/8” (54 mm) MIN.

4-1/8” (105 mm) MAX.

2” (51 mm) OPENING IN WALL

(CONNECTION THROUGH WALL

NOT SUPPLIED BY SLOAN)

“L” DIM

2-3/4” (70 mm)

+ WALL THICKNESS

14-1/2”

(368 mm)

2-1/8” (54 mm) MIN.

4-1/8” (105 mm) MAX.

2” (51 mm) OPENING IN WALL

(1-1/2” (38 mm) CONNECTION

THROUGH WALL NOT SUPPLIED

BY SLOAN)

“L” DIM

2-3/4” (70 mm)

+ WALL THICKNESS

13-1/2”

(343 mm)

1” (25 mm) OPENING IN WALL

(3/4” (19 mm) CONNECTION

THROUGH WALL NOT SUPPLIED

BY SLOAN)

1-1/2” (38 mm) MIN.

4-1/2” (114 mm) MAX.

“L” DIM

2-3/4” (70 mm)

+ WALL THICKNESS

24-1/2”

(622 mm)

2-1/8” (54 mm) MIN.

6-1/8” (156 mm) MAX.

2” (51 mm) OPENING IN WALL

(1-1/2” (38 mm) CONNECTION

THROUGH WALL NOT SUPPLIED

BY SLOAN)

“L” DIM

6-3/4” (171 mm)

+ WALL THICKNESS

ROUGH-INS