beautypg.com

Sensoray 826 User Manual

Page 76

background image

Watchdog Timer
Timer stages

Number

3

Interval (per stage)

Programmable from 1 to 2

32

-1 * 20 ns (20 ns to ~85.9 s)

Output events

Stage 0: Fail-safe trigger, IRQ
Stage 1: NMI out via digital output, PCIe Fatal Error
Stage 2: Reset via digital output or onboard solid state relay (SSR)

Solid state relay
(Reset out)

On-state resistance (I

L

= 10mA)

20 ohms typical, 30

max.

Off-state leakage current

0.03 µA typical, 1.0 µA max.

Applied voltage (maximum)

200 V

Load current (maximum)

100 mA

Power and Environmental
Power

Input power

350 mA (+12V) and 450 mA (+3.3V), nominal, with no loads

Encoder power out

5 VDC ±5%, 400 mA max. (total for all encoders)

Temperature

Operating

0 to 70

º

C

Mating Connectors
(not included)

Counters

Sullins SFH210-PPPC-D13-ID-BK or equivalent (qty. 2)

Analog I/O

Sullins SFH210-PPPC-D25-ID-BK or equivalent (qty. 1)

Digital I/O

Sullins SFH210-PPPC-D25-ID-BK or equivalent (qty. 2)

826 Instruction Manual

71

Specifications