beautypg.com

Sensoray 826 User Manual

Page 51

background image

Register

Value

Mode

0x00000000

Preload0

0x00000000

Periodic Timer

Periodically capture snapshots.

Register

Value

Mode

0x00402020

Snapshot Configuration

0x00000004

Preload0

Period in µs

Delay Timer

Call S826_CounterPreload to start the timer, then S826_CounterSnapshotRead to wait for the delay time to elapse.

Register

Value

Mode

0x00400520

Snapshot Configuration

0x00000004

Preload0

Delay in µs

Frequency Measurement

Measure frequency by counting clocks applied to the ClkA input for one second intervals. At the end of each interval, a
snapshot is captured and the next measurement begins automatically. The snapshot counts indicate measured frequency
in Hz.

Register

Value

Mode

0x00008009

Snapshot Configuration

0x00000010

Preload0

0x00000000

Period Measurement

Measure the period of a signal applied to the IX input by counting internal clocks during one input cycle. At the end of
each cycle, a snapshot is captured and the next measurement begins automatically. The snapshot counts indicate
measured period in µs.

Register

Value

Mode

0x00008020

Snapshot Configuration

0x00000010

Preload0

0x00000000

Pulse Width Measurement

Measure the width of pulses applied to the IX input by counting internal clocks during one pulse. At the end of each
pulse, a snapshot is captured and the next measurement begins automatically. The snapshot counts will indicate the
measured pulse width in µs.

826 Instruction Manual

46

Counters