REMKO SV 261 User Manual
Page 11

The NETWORK button has not been as-
signed a function.
NETWORK Button
SLEEP Button
Mode HEAT
Press the MODE button once or repeatedly to switch to heating mode.
Use this mode to heat the room air to the desired target temperature.
The fan will only start when the fin temperature reaches 38°C.
Press the TEMP
/
buttons to set the desired room temperature in
1 °C steps. If the room temperature falls 1 °C below the set target
temperature, heating mode is activated. f the actual temperature rises
approx. 1 °C above the set room temperature, the controller switches the
heating off.
MODE
HEATINg MODE
It is recommended that the
target temperature is set to
max. 28 °C. Maximum fan
speed and the lowest fin
setting should also be used.
NOTE
After the SLEEP button is pressed, the symbol is shown on the display
and the room temperature is raised or lowered by 0.5 °C in cooling and
heating mode respectively 30 minutes after the function starts up. After
a further 30 minutes the room temperature is raised or lowered by 1 °C
in cooling and heating mode respectively. After a further hour the room
temperature is held at a constant 2°C above or below the original target
temperature in cooling and heating modes respectively. The temperature
is then maintained at a constant level. This function is disabled by
pressing the POWER or SLEEP button. The symbol on the display
extinguishes.
SLEEP
SLEEP
SLEEP
SLEEP
HEATINg MODE:
COOlINg MODE
11