The units are shipped in sturdy

transport packaging. Immediately

check the units on delivery and

make a note of any damage or

missing parts on the delivery note.

Inform the forwarding agent and

contractual partner. Warranty

claims at a later date will not be

accepted.

RXT 351-1401DC room air

conditioning units have a REMKO

RXT...DC AT outdoor component

as well as an RXT...DC IT indoor

unit.
When in cooling mode, the

outdoor component serves to

release the heat extracted by the

indoor unit from the room being

cooled into the outside air. In

heating mode, the heat absorbed

by the outdoor component can

be discharged through the indoor

unit into the room being heated.

SFlbIn both operating modes, the

performance of the compressor

precisely adjusts itself to the

demand, thereby regulating the

nominal temperature with minimal

temperature variations. This

"inverter technology" results in

energy savings over conventional

split systems and also reduces

noise emissions to a particularly

low level.

The outdoor component can

be installed outdoors or indoors

providing that certain requirements
are met. The unit is designed both
for both wall and ceiling-mounted
indoor operation. Operation takes
place using an infrared remote
control. The outdoor component

consists of a refrigerant circuit

with compressor, fin condenser,

condenser fan, reverse flow valve

and electronic expansion valve

(RXT 521-1401DC). The outdoor

component is controlled by the

controller in the indoor unit.

The indoor unit consists of a fin

vaporiser, vaporiser fan, controller

and condensation pan.
Floor consoles, wall consoles,

refrigerant pipes, wired remote

controls and condensation pumps

are available as accessories.

System description

Transport and
packaging

The connection between the indoor unit and the outdoor component is
made by way of the refrigerant lines.

M1 - Condenser fan

M2 - Compressor

M3 - IU vaporiser fan

V1 - C/H switching valve

EEV - Electr. expansion valve

PSH - OC high pressure switch

PSL - OC low pressure switch

T1 - OC hot gas sensor

T2 - OC air intake sensor

T3 - OC condenser sensor

T4 - IU air intake sensor

T5 - IU vaporiser sensor

Diagram of the series RXT 351-1401DC refrigerant circuit

Filter

Filter

Filter

Filter

System layout

Outdoor component

Shut-off valve

Indoor unit

Condenser fan

Outdoor area

Injection line

Suction line

Control cable

Condensate line

Interior ceiling installation

Condensate line

Mains cable

Indoor area

Outdoor area

M1

M2

M3

T4

T2

T3

T5

T1

RXT 351 DC

V1

EEV

RXT 1051 DC

M

M

P S H

T1

T2

T3

TE

T5

P S L

T2

T3

T4

T5

M3

M2

M1

PSL

PSH

T1

Oil r

eturn line

V1

RXT 521 DC

M

M

TE

P S H

T1

T2

T3

T5

P S L

M1

M3

T2

T3

T4

T5

M2

PSL

PSH

T1

Filter

V1

EEV

RXT 521-681 DC

RXT 1051-1401 DC

5