DEHUMIDIFICATION mode
It is recommended that the target temperature be set to 24°C in
dehumidification mode. Due to the low temperature of the refrigerant,
the temperature of the air at the condenser falls below the dew point.
The excess moisture in the air is condensed by the vaporiser, the room is
dehumidified.
DEHUMIFICATION
MODE
MODE
HEATING mode
In heating mode, you can heat the room in spring or autumn.
The selected room temperature is set using the
▲/▼ keys in 1 °C
increments. If the room temperature is 1 °C below the selected target
temperature, the indoor unit starts to heat the air in the room. If the set
room temperature is exceeded by approx. 1 °C, the controller will switch
off heating mode. To protect the compressor, the controller will wait 3
minutes before switching on the heating mode again.
MODE
HEATING MODE
COOLING mode
In cooling mode, the air in the room is cooled down to the selected target
temperature. The desired room temperature is set with the
▲/▼ keys
in 1 °C increments. If the room temperature is 0.5 ℃ above the selected
target temperature, then the interior unit starts to cool down the air in
the room. If the temperature falls to approx. 1 °C below the set room
temperature, the controller will switch off cooling mode℃. To protect the
compressor, the controller will not switch cooling mode back on again
until a delay of 3 minutes has elapsed.