3 design and function, 1 equipment description, Design and function 3.1 equipment description – REMKO MXD 202 User Manual

Page 9: Design and function, Equipment description

background image

3

Design and function

3.1

Equipment description

The indoor unit serves to extract heat from the

indoor room being cooled. The outdoor unit then

expels this heat to the outside.

If combined heating/cooling units are operated as

heaters, the heat absorbed by the outdoor unit can

be discharged by the indoor unit into the room

being heated.

The unit series has priority "heating", this means

that units that are in heating or automatic mode,

other units in the system that are in cooling mode

can switch off.

The unit is designed for installation high up on

indoor walls.

Operation takes place using an infrared remote

control.

The indoor unit consists of a fin vaporiser, vapor-

iser fan, controller and condensation pan.

The indoor unit can be combined with REMKO out-

door units of series MVT 601DC, 901DC und

1051DC with sufficient combinations. The outdoor

component is controlled via the controller of the

indoor unit.

Cabled remote control and condensation pump are

available as an accessory.

B

A

4

3

5

6

1a

1b

2

7b

3

3

7a

8b

8a

9b

9a

Fig. 2: System layout

(In this example: MVT 901 DC with 2 MXD 352)

A:

Outdoor area

B:

Indoor area

1 a,b: Indoor units

2:

Outdoor unit

3:

Condensate drain

4:

Condenser fan

5:

Power output

6:

Shut-off valve

7 a,b: Suction pipe

8 a,b: Injection pipe

9 a,b: Control line

Refrigerant pipes are used to connect the indoor

unit to the outdoor unit.

2

1

4

3

Fig. 3: Schematic of refrigerant circuit

1: Evaporator

2: Evaporator fan

3: Connection suction pipe

4: Connection injection pipe

9