"Automatic" mode

In automatic mode, the controller autonomously

selects between heating, circulation or cooling

mode based on the room temperature Tr and the

selected target value Ts. The target value can be

adjusted between 17°C and 30°C by means of the

" " and " ". The fan speed is selected automati-

cally.

Fig. 12: "Automatic" mode

Funktion:

Tr"Heating" is

selected.

Tr>Ts=2 °C, then operating mode "Cooling" is

selected.

Tr<-1 °C...Ts...+2 °C, then operating mode "Circu-

lation" is selected.

If after the compressor is shut down and not

required for more than 15 mins. within an operating

mode, then, in the event that the room temperature

deviates, the corresponding mode heating,

cooling or circulation will be selected again.

The heating mode has priority!

Turns on the indoor unit to the heating mode,

switch off the other indoor units from which are

in cooling mode, the cooling. During heating

operation can not be cooled.

„Dehumidification“ mode

It is recommended that the target temperature be

set to 24°C in dehumidifying mode. Due to the low

temperature of the refrigerant, the dew point of the

air at the condenser is undercut. The excess mois-

ture in the air is condensed by the vaporiser, the

room is dehumidified.

Fig. 13: "Dehumidification“ mode

„Cooling“ mode

In cooling mode, the air in the room is cooled down

to the adjusted nominal temperature. The desired

room temperature is set with the " " and " " keys

in 1 °C increments. If the room temperature is 0.5

°C above the selected nominal temperature, then

the interior unit starts to cool down the air in the

room. If the temperature falls to approx. 1 °C below

the set room temperature, the controller will switch

off the cooling function. To protect the compressor,

the controller only turns cooling on again after a

waiting period of 3 minutes.

Fig. 14: „Cooling“ mode