QuickLabel R-310 QuickWrap User Manual
Page 20

20
OPTIONAL LION SENSOR FOR CLEAR LABELS
Important:
x Web must remain in contact with mounting plate.
x Label must pass under the sensor indicator
x Small labels should be centered under sensor.
x When properly setup, the lights will move between WEB and LABEL. The
lights in the “X” region should only light briefly during the transition
between WEB and LABEL.
Basic (Low Gain) Setup (effective for 90% of labels):
1. Adjust
SPAN
to minimum (four turns counter-clockwise)
2. While moving labels through the sensor.
a. Adjust shift toward L
(LABEL)
until the last web light does NOT light.
b. Adjust shift toward W
(WEB)
until the last web light DOES light.
3. Setup complete.
4. If there is any false triggering, missed labels, or lights in the “X” region
except during transition, change to medium gain setup. (See Fig 14)
Basic Gain Setup:
1. Adjust
SPAN
to mid-point (four turns counter-clockwise, two rotation
clockwise)
2. Repeat steps 2 & 3 from Basic setup above.
3. If there is any false triggering, missed labels, or lights in the “X” region
except during transition, change to high gain setup. (See Fig 14)
High Gain Setup:
1. Adjust
SPAN
to maximum (four turns clockwise)
2. Repeat steps 2 & 3 from Basic setup above. (See Fig 14)
“X” area
“SHIFT”
“SPAN”
Mounting Plate
Fig 14