beautypg.com

QuickLabel QLS-4100 Xe User Manual

Page 52

background image

4-6

Keypad controls and menus

Operation Menu

Options are available in a Pause state only.

Pull Back

Requires special hardware. Contact QuickLabel
Systems for more information on this function.

Label Reprint

Reprints up to 999 copies of the last label printed, if
using the Windows print driver.

Synchronize Labels

Synchronizes labels when using printer/applicator
or Print & Peel.


Ribbon Menu

Options are available in a Pause state only.

Ribbon Type

Selects printhead intensity tailored to a specific
media type. Possible values are Standard and
Resin/Synthetic.

Drop/Lift Adjust

Adjust the drop and lift point for printheads 1 – 4.
Possible values are 0 to +40 mm.

Ribbon Sensor

Used by QuickLabel Systems’ technicians when
performing factory diagnostics. Possible values are
Enabled and Disabled, but in general use, the
sensor should always be enabled.

Communications
Menu

Options are available in a Pause state only.

Data Port

Selects the data input interface used by the printer.
Possible values are Parallel, Serial, or Ethernet.

Parallel Mode

Specifies the mode of connection for the parallel
port. Possible values are Auto or Standard.

RS232 Baud Rate

Specifies a baud rate for the RS232 serial port.
Possible values are 4800, 9600, 19200, or 38400.

RS232 Handshaking

Specifies a handshaking method for the RS 232
serial port. Possible values are Hardware or
XON/XOFF.

TCP/IP Address

Specifies the IP address of the printer for ethernet
purposes.