3-12

Loading media and calibration

10 Reposition the media by pressing and holding the FORM

FEED/ADVANCE key until the red light no longer shines through the
mark but through the media.

11 Press the SELECT key. The display will show the following prompt:

12 Press

and

hold the FORM FEED/ADVANCE key until the reflective mark

is positioned behind the Media Sensor Assembly and in close proximity
to the guide arrow indicated on the center plate.

13 Press the SELECT key. If calibration was successful, the following

message will be displayed:

If calibration was unsuccessful, the following message will be displayed:

The user must re-initiate the calibration procedure.

14 After successful calibration, press the PRINT/PAUSE key to return the

printer to a Ready state.

Reflective
Calibration Bad

Reflective
Calibration OK

Place Mark @ Arrow
Then Press Select