QLS-4100 Xe

2-13

Utility Port Connection

On the rear panel of the printer, the Utility Port permits connection to
external devices such as the optional QuickLabel Systems Cutter and
Cutter/Stacker or a label applicator system. The assignment of pin functions
on the utility port depends on the mode of operation. For information
regarding applicator mode operation, please contact QuickLabel Systems.

Warning: Exceeding the limits of the utility port signals can result in damage
to the printer.

Standard Mode
Pin

Signal

Notes

1

N/C

2

Ground

3

Cutter On/Off Output (1=on 0=off)

4

5 VDC

1A max

5

Cutter

Error Input (1=error 0=no error)

6

Cutter Pulse

4-6 ms pulse output

7

N/C

8

Pause

Input

(1=print 0=pause)

9

Error

5

1

9

6

Applicator Mode
Pin

Signal

Notes

1

N/C

2

Ground

3

Printing

Output (1=printing)

4

N/C

5

N/C

6

N/C

7

N/C

8

Go

Input (1=initiate print)

9

Skip/Apply

Output (1=apply 0=skip)

Notes: If you are using a cutter or cutter/stacker, refer to the unit’s setup and
operation manual for information on setting up the unit with your printer.

Functionality may be modified via host commands. For information, see the
QuickLabel Systems Programmer's Reference (PN 14004017).