Utility port connection – QuickLabel QLS-4100 Xe User Manual
Page 31

QLS-4100 Xe
2-13
Utility Port Connection
On the rear panel of the printer, the Utility Port permits connection to
external devices such as the optional QuickLabel Systems Cutter and
Cutter/Stacker or a label applicator system. The assignment of pin functions
on the utility port depends on the mode of operation. For information
regarding applicator mode operation, please contact QuickLabel Systems.
Warning: Exceeding the limits of the utility port signals can result in damage
to the printer.
Standard Mode
Pin
Signal
Notes
1
N/C
2
Ground
3
Cutter On/Off Output (1=on 0=off)
4
5 VDC
1A max
5
Cutter
Error Input (1=error 0=no error)
6
Cutter Pulse
4-6 ms pulse output
7
N/C
8
Pause
Input
(1=print 0=pause)
9
Error
5
1
9
6
Applicator Mode
Pin
Signal
Notes
1
N/C
2
Ground
3
Printing
Output (1=printing)
4
N/C
5
N/C
6
N/C
7
N/C
8
Go
Input (1=initiate print)
9
Skip/Apply
Output (1=apply 0=skip)
Notes: If you are using a cutter or cutter/stacker, refer to the unit’s setup and
operation manual for information on setting up the unit with your printer.
Functionality may be modified via host commands. For information, see the
QuickLabel Systems Programmer's Reference (PN 14004017).